21
TROUBLESHOOTING GUIDE
FAULT
CAUSE
REMEDY
Pump is running but does not
reach rated pressure
Pump sucking air
Check hose / fittings for leaks
Nozzle is blocked / worn
Remove and clean nozzle
Water filter dirty
Check and clean water filter
Fluctuating pressure
Pump sucking air
Check hose / fittings for leaks
Nozzle is blocked / worn
Remove and clean nozzle
Water filter dirty
Check and clean water filter
Pump is noisy
Pump sucking air
Check hose / fittings for leaks
Appearance of “milky” oil in
the pump
Contact Spitwater service agent
Water leaking from pump
Contact Spitwater service agent
Oil leaking from pump
Contact Spitwater service agent
The motor does not start
when switch is activated.
Plug is not connected.
Check the plug.
If fitted: Low water cut off is
activated.
Check that water / diesel tank
are full and add water / diesel as
necessary.
No power supply.
Contact an authorized
electrician to check power
supply.
When switch is activated the
motor hums but does not run.
Incorrect extension cable.
See instructions in manual and
replace with an extension cord
of correct size and length.
Incorrect or insufficient voltage
or amperage.
Contact an authorized
electrician to check power
supply.
Failed capacitor
Contact Spitwater service agent
The motor stops
Contact Spitwater service agent
TROUBLESHOOTING GUIDE
TABLE-C: Trouble shooting guide-PUMP
For service of your Spitwater high pressure cleaner within Australia, call 1800SPITWATER or
visit www.spitwater.com.au.
If the fault cannot be identified or corrected using the below list (or remedy suggests contacting
Spitwater service agent) stop using the unit immediately and contact your authorized Spitwater
service agent to rectify.