Spitwater HP18160E GT Operating And Maintenance Manual Download Page 2

 

 2 

 

Spitwater  Australia  is  proudly  Australian  owned  and  operated  since  1983.  Our  promise  is  to  provide  our 
customers with superior quality high pressure cleaners built to the highest of standards that will see many years 
of reliable service. 
The Spitwater range of high pressure cleaners has been designed to give safe, efficient and dependable service 
when  the  correct  operating  and  safety  instructions  are  followed  and  proper  attention  is  given  to  all  required 
maintenance procedures in order to maintain the unit in peak operating condition. 
This manual provides the up to date information necessary for the user to operate the unit and carry out regular 
inspection and maintenance. 
Please note that the information given within this manual may be subject to revision in compliance with Spitwater 
Australia’s policy of continual improvement. 
Spitwater high pressure cleaners should only be used in the manner and purpose for which they

 

were intended 

and in accordance with the recommendations and safety precautions detailed in this manual.  
All Spitwater high pressure cleaners undergo rigorous safety and operational tests before being dispatched into 
the market, however it is still imperative that prior to use, all operators have read and understood all information 
and instructions provided and are aware of possible hazards. 

 
 
 

Spitwater high pressure cleaners are specifically designed to solve all problems relating to washing, degreasing, 
descaling  and  disinfecting  in  a  wide  range  of  commercial  and  industrial  situations.  Some  examples  of 
applications are in the cleaning, building, transport, light and heavy manufacturing and primary industries. 

 
 
 

Spitwater has an extensive range of spare parts and accessories to suit all your cleaning needs. For spare parts, 
accessories and service please contact 

1800 SPITWATER (1800 774 892)

 and to view Spitwater's extensive 

range of high pressure cleaners online visit 

www.spitwater.com.au 

For international spare parts, accessories and service please contact 

[email protected]

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

INTRODUCTION 

GENERAL DESCRIPTION & INTENDED USE 

SPARE PARTS, ACCESSORIES AND AFTER SALES SERVICE 

Summary of Contents for HP18160E GT

Page 1: ...this instruction manual before operating this unit and retain for future reference Failure to follow operating safety and maintenance instructions outlined in this manual releases the manufacturer fr...

Page 2: ...accordance with the recommendations and safety precautions detailed in this manual All Spitwater high pressure cleaners undergo rigorous safety and operational tests before being dispatched into the m...

Page 3: ...7 5 HP PUMP MODEL HTS6311 HT4718 OIL TYPE 15W 40 15W 40 OIL CAPACITY 0 36 1 1 L OTHER DETERGENT BOTTLE CAPACITY L VALUES DETERMINED AS PER AS NZS 60335 2 79 SOUND PRESSURE LEVEL Lp 75 78 4 dB A UNCER...

Page 4: ...t cautious Their meaning is listed next to them for your attention CAUTION Electric shock hazard Disconnect power before removing cover DESCRIPTION OF SYMBOLS IMPORTANT SAFETY INSTRUCTIONS AND PRECAUT...

Page 5: ...ON OFF SWITCH HIGH PRESSURE HOSE PRESSURE LOW HIGH PLUG SCW83 G ONLY DUAL LANCE CHEMICAL SUCTION HOSE HIGH PRESSURE WATER OUTLET CONNECTOR Always pay attention to the safety instructions provided on...

Page 6: ...ent PPE 2 ELECTRICAL CONNECTION The voltage hertz rating and number of phases on the serial label must correspond to that of the electrical mains outlet Only connect the unit to electrical installatio...

Page 7: ...unit s power cord 6 TRIP HAZARD Loose extension cords and power cables provide a potential trip hazard especially when they cross pathways Take safety measures like placing traffic cones along the co...

Page 8: ...er is subject to very strong recoil forces and torque There is a risk of high pressure water jet injury Never aim the jet at yourself other people or animals as this could result in serious injuries o...

Page 9: ...amage to the unit Spitwater recommends the use of original accessories and spare parts available through Spitwater and its extensive dealer network Never use a nozzle size other than that specified in...

Page 10: ...t it from sliding or falling 4 If transporting the unit make sure there is no possibility for the temperature to be at or below 0 C If it is necessary to transport the unit at or below 0 C contact you...

Page 11: ...ed on the data plate and in the technical data in this manual This unit must be earthed Please note that incorrect voltage or insufficient power supply will cause immediate damage to the unit Note Any...

Page 12: ...do not interchange during assembly Add nozzle shield after nozzle assembly Refer diagram below 12 LANCE TRIGGER GUN HIGH PRESSURE HOSE ASSEMBLY Connect the lance to the spray gun by an in built quick...

Page 13: ...vice agent if found Open the water supply and fill the water tank The float valve will automatically stop the water flow when the water tank is full Water that has flowed through backflow preventer is...

Page 14: ...he spray gun a few times to expel Note If this is the first use of the unit or the unit has been left idle for an extended period of time it is advisable to run this operation with the front part of t...

Page 15: ...acid or corrosive products contact an authorized service agent or the manufacturer if in doubt 2 If detergent is required it CAN BE USED IN LOW PRESSURE ONLY To activate low pressure turn the lance h...

Page 16: ...d water pressure in the unit by pulling the trigger of the spray gun then engage the spray gun trigger lock Failure to follow this instruction will leave the unit in a potentially unsafe manner 5 If t...

Page 17: ...ents that have been set and sealed at the factory Never under any circumstances tamper with modify or adjust these settings 7 Make sure this unit is regularly serviced by an authorized Spitwater servi...

Page 18: ...r units subjected to normal operating conditions Should the unit be subjected to abnormal conditions e g heavy use dirty water extreme temperatures or conditions etc times should be reduced accordingl...

Page 19: ...appearance Check for any service due based on USAGE VS SERVICE FREQUENCY Table A Check pressure gauge to show working pressure as per Technical data sheet when the trigger is in ON position Check for...

Page 20: ...unit is on a flat surface Check the oil level in the pump using the dipstick or the sight glass on the back side of the pump Make sure the level is between min max level notches on the dipstick or is...

Page 21: ...w water cut off is activated Check that water diesel tank are full and add water diesel as necessary No power supply Contact an authorized electrician to check power supply When switch is activated th...