Page 48 of 54
N.B. If the display returns to the one shown above with the word “TESC”
shown, then too much time has passed before pressing “SET” and so the
handset has not paired yet. Simply repeat pairing again.
N.B. Only ever press “+” and “-“ buttons together when pairing handsets. If
done afterwards this will break the pairing made and a factory reset of the
handset will need to be performed See Factory Reset of display handset later on
in the instructions.
Snooze (in manual mode)
Snooze mode is a time period you can set which will turn off the fire after a
certain time period has elapsed.
The snooze time period can be set before or during manual operation of the fire.
Hold the handset to unlock as described previously and press the mode button
as many times as necessary until the word MAN and the Zzz symbols are
flashing at the top of the display. Press and release the set button and this will
put the control into Manual snooze mode.
The default time period for the snooze time period is 1:00 hour. Pressing the set
button again will show you the snooze time period remaining. This can be
adjusted by pressing the “+” or “-“ buttons. The timer period that can be set is
from 1 minute to 4:00 hours.
After adjusting the time, press set again to enter the time setting required (or if
left for a few seconds this time is now stored and used).
Once this countdown timer has reached zero the fire will turn off (as if you had
pressed off manually, it does not recycle).
Snooze (in thermostatic mode)
The same thing as above can be done before or during a thermostatic mode
operation (see below).