Description of FR-850 Design
This appliance is supplied as a complete suite of gas fire burner unit with
remote control and enclosure, there is an optional gather. To comply with the
approval this fire must be installed as designed. There are two versions which
can be purchased by the customer depending on site specific conditions like
chimney size and room ventilation. Read this booklet carefully and check the
delivery paperwork and data plate inside the fire to confirm which version is to
be installed.
The versions are:
•
FR850 – (Natural Gas or LPG) - This version has a minimum flue
requirement of 178mm diameter or Class 1 chimney at 2m in length. This
version needs room ventilation with a 100cm2 air vent to the outside air.
•
FR850NV – (Natural Gas Only) - This version has a minimum flue size of
127mm diameter flue or Class 2 chimney at 3m in length. This version does
not need room ventilation. The enclosure on this version features a glass
panel to reduce the opening. This glass panel must be fitted at the factory at
time of order. This version of the fire must not be operated without the glass
panel fitted.
If the fire has been delivered to site with the glass panel then the
fire must never be operated without the glass in place. Refer to the
Data Plate. If the glass is damaged a replacement must be
purchased from the manufacturer.