IM-P113-04
CMGT Issue 2
7
UIB45 Sealed Inverted Bucket Steam Trap for use with Pipeline Connectors
2.3 Pressure/temperature limits
The product
must not
be used in this region.
Note:
The model of pipeline connector and connections selected will dictate the maximum operating
pressure and temperature of the complete assembly. Consult the specified Technical Information Sheet for
this information (see Section 2.2).
Body design conditions
ASME 600
PMA
Maximum allowable pressure
99.3 bar g @ 38
°C
(1 440 psi g @ 100
°F)
TMA
Maximum allowable temperature
425
°C @ 56 bar g
(797 °F @ 812 psi g)
Minimum allowable temperature
-29
°C
(-20.2
°F)
PMO
Maximum operating pressure for saturated steam service
63 bar g
(914 psi)
TMO
Maximum operating temperature
425
°C @ 56 bar g
(797
°F @ 812 psi g)
Minimum operating temperature
0
°C
(32
°F)
D
PMX Maximum differential pressure
UIB45/5
45 bar
(652 psi)
UIB45/6
20 bar
(290 psi)
UIB45/8
8.5 bar
(123 psi)
UIB45/10
4.5 bar
(65 psi)
Designed for a maximum cold hydraulic test pressure of:
149 bar g
(2 161 psi g)
Te
mp
er
atu
re
°C
Pressure bar g
Pressure psi g
Te
mp
era
tu
re
°F