Spirax Sarco UIB45 Installation And Maintenance Instructions Manual Download Page 4

IM-P113-04 

CMGT Issue 2

4

UIB45 Sealed Inverted Bucket Steam Trap for use with Pipeline Connectors

1.5  Hazardous environment around the product

Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, extremes of 

temperature, hot surfaces, fire hazard (e.g. during welding), excessive noise, moving machinery.

1.6  The system

Consider the effect on the complete system of the work proposed. Will any proposed action (e.g. 

closing isolation valves, electrical isolation) put any other part of the system or any personnel at risk? 

Dangers might include isolation of vents or protective devices or the rendering ineffective of controls 

or alarms. Ensure isolation valves are turned on and off in a gradual  way  to  avoid  system  shocks.

1.7  Pressure systems 

Ensure that any pressure is isolated and safely vented to atmospheric pressure. 

Consider double isolation (double block and bleed) and the locking or labelling of closed valves. 

Do not assume that the system has depressurised even when the pressure  gauge  indicates   zero.

1.8 Temperature

Allow time for temperature to normalise after isolation to avoid the danger of burns. 

1.9  Tools and consumables

Before starting work ensure that you have suitable tools and /or consumables available. Use only 

genuine Spirax Sarco replacement parts.

1.10  Protective clothing

Consider whether you and /or others in the vicinity require any protective clothing to protect against 

the hazards of, for example, chemicals, high/low temperature, radiation, noise, falling objects, and 

dangers to eyes  and  face.

1.11  Permits to work

All work must be carried out or be supervised by a suitably competent person.

Installation and operating personnel should be trained in the correct use of the 

product   according   to   the   Installation   and   Maintenance   Instructions.

Where a formal 'permit to work' system is in force it must be complied with. Where there is no such 

system, it is recommended that a responsible person should know what work is going on and, where 

necessary, arrange to have an assistant whose primary  responsibility  is  safety.

Post ‘warning notices’ if necessary.

1.12 Handling

Manual handling of large and/or heavy products may present a risk of injury. Lifting, pushing, 

pulling, carrying or supporting a load by bodily force can cause injury particularly to the back. 

You are advised to assess the risks taking into account the task, the individual, the load and the 

working environment and use the appropriate handling method  depending on the  circumstances 

of the  work  being  done.

Summary of Contents for UIB45

Page 1: ...1 Safety information 2 General product information 3 Installation 4 Commissioning 5 Operation 6 Maintenance 7 Spare parts Copyright 2022 Printed in GB 1133550 2 UIB45 Sealed Inverted Bucket Steam Trap...

Page 2: ...IM P113 04 CMGT Issue 2 2 UIB45 Sealed Inverted Bucket Steam Trap for use with Pipeline Connectors...

Page 3: ...if this is contemplated Spirax Sarco should be contacted to confirm the suitability of the product for the application being considered ii Check material suitability pressure and temperature and thei...

Page 4: ...s Before starting work ensure that you have suitable tools and or consumables available Use only genuine Spirax Sarco replacement parts 1 10 Protective clothing Consider whether you and or others in t...

Page 5: ...in environments where they may be exposed to temperatures below freezing point 1 15 Disposal Unless otherwise stated in the Installation and Maintenance Instructions this product is recyclable and no...

Page 6: ...a variety of different pipeline connectors including PC10 Straight connector ASME 300 see TI P128 10 PC10HP Straight connector ASME 600 see TI P128 10 PC20 Straight connector with Y type strainer ASME...

Page 7: ...PMA Maximum allowable pressure 99 3 bar g 38 C 1 440 psi g 100 F TMA Maximum allowable temperature 425 C 56 bar g 797 F 812 psi g Minimum allowable temperature 29 C 20 2 F PMO Maximum operating press...

Page 8: ...e 1 Open isolation valves slowly until normal operating conditions are achieved 3 5 Inverted bucket steam traps do not permit rapid release of air On process applications in particular this can lead t...

Page 9: ...Fig 3 Pipeline connector 10 Fig 2 UIB45 Inverted bucket steam trap Table 1 Recommended tightening torques for suitably lubricated threads Item Part mm N m lbf ft 10 Connector screws 9 16 A F 30 35 22...

Page 10: ...lel to the connector Tighten the screws evenly and gradually to the recommended torque see Table 1 Open isolation valves slowly until normal operating conditions are achieved Check for leaks As conden...

Page 11: ...ket set 10 11 12 How to order spares Always order spare parts by using the description given in the column headed Available spares and state the size model no and pressure rating of the trap Example 1...

Page 12: ...IM P113 04 CMGT Issue 2 12 UIB45 Sealed Inverted Bucket Steam Trap for use with Pipeline Connectors...

Reviews: