IM-P361-02-EN-ISS1
CTLS
10
start of text under grey section header box
start of text continuing from previous page
TRANSLATION RUN OVER
Note: When lifting the
actuator only use a
lifting sling through X1
to X4.
X4
X3
X1
X2
Actuator data:
Actuator
range
Travel
Thrust
Acting
pressure
0 mm
Acting
pressure
20 mm
Acting
pressure
30 mm
Acting
pressure
50 mm
TN2030 and
variants
30 mm
2.5 kN
562 lbf
0.79 bar
11.50 psi
1.47 bar
21.31 psi
1.81 bar
26.24 psi
TN2033 and
variants
30 mm
6 kN
1 349 lbf
1.89 bar
27.40 psi
4.19 bar
60.80 psi
5.34 bar
77.49 psi
TN2150 and
variants
50 mm
3.6 kN
809 lbf
0.46 bar
6.70 psi
1.12 bar
16.27 psi
1.45 bar
21.06 psi
2.11 bar
30.64 psi
TN2153 and
variants
50 mm
14 kN
3 147 lbf
1.95 bar
28.30 psi
2.73 bar
39.58 psi
3.12 bar
45.23 psi
3.90 bar
56.54 psi
Caution:
Those pressure ranges are estimated and directly related to the springs precision ( ±10%).
Furthermore, the working pressure with the valve coupled can be a little bit upper because of the friction
inside of it.
Fig. 3