4.2 Performance selection
(with primary pressure 10 bar)
For any specified primary filtration pressure, there is a maximum recommended air flowrate.
Keeping within this, will ensure that the element performance maintains the stated high
efficiency levels, particularly for the removal of oil and water contaminants.
¼"
Key for all charts
4.3 Capacities
With primary pressure 10 bar and 5 μm element
Air flow scfm
Secondary pressure bar
Secondary pressure psi
Air flow dm
3
/s
1.6 bar g (23 psi g)
2.5 bar g (36 psi g)
4.0 bar g (58 psi g)
6.3 bar g (91 psi g)
8.0 bar g (116 psi g)