10.7 Output technical data
Probe cleaning
Maximum voltage
32 Vdc
Drive
CONSTANT (dc) or PULSED, 1 second on, 1 second off.
4-20 mA(s)
Minimum current
0 mA
Maximum current
20 mA
Open circuit voltage (maximum) 19 Vdc
Resolution
0.1% FSD
Maximum output load
500 ohm
Isolation
100 V
Output rate
10 / second
Relay(s)
Contacts
2 x single pole changeover relays (SPCO)
Voltage ratings (maximum)
250 Vac
Resistive load
3 amp @ 250 Vac
Inductive load
1 amp @ 250 Vac
ac motor load
¼
HP (2.9 amp) @ 250 Vac
1
/
10
HP (3 amp) @ 120 Vac
Pilot duty load
C300 (2.5 amp) - control circuit / coils
Electrical life (operations)
3 x 10
5
or greater depending on load
Mechanical life (operations)
30 x 10
6
RS485
Physical layer
RS485 4-wire full or 2-wire half duplex
Protocol
Modbus RTU format
Isolation
60 Vac / dc
Receiver unit load
(256 devices - maximum)
Output rate
Up to 10 frames / second
Infrared
Physical layer
IrDA
Baud
38400
Range
10 cm
Working angle
15
°
Eye safety information
Exempt from EN 60825-12: 2007 Safety of laser
products ~ does not exceed the accessible emission
limits (AEL) of class 1