SpinetiX SA, Switzerland
11
At the end of the booting process, the screen will start displaying the animated SpinetiX logo. This is the default content. The LED
(‘SYS’ Led on HMP200) blinks regularly on and off once per second to indicate normal operation.
HMP splash screen (power up)
Troubleshooting
If the HMP does respond as described, check the following:
1.
Check the display is functional and that the right input has been selected.
2.
Check the cables connecting the HMP to the screen and try alternative cables.
3.
If the HMP displays the SpinetiX logo on a blue background and then the screen signal disappears, your screen is not being
properly detected by the HMP. Open the web interface, then under the "
Display Settings
" page, set "
Power mode for VGA
output
" to "
Always On
".
Support Wiki keyword:
SpinetiX Support