9 Repair
Thermo 230 / 231 / 300 / 301 / 350
91
0
9.2.8 Igniter Box, Replacement
9.2.8.1 Removal
1. Remove burner if required (refer to 9.2.3.1).
2. Using screw driver lever off igniter electrodes
(Fig. 904) from igniter box and remove.
3. Remove disk (6).
4. Remove screws (2) with lock washers.
5. Withdraw igniter box (1) and remove.
6. Perform procedures on components after
disassembly (refer to 9.1.1).
9.2.8.2 Installation
1. Locate igniter box (1, Fig. 904) for installation, plug on
making correct electrical connections and secure with
screws (2) and lock washers.
2. Tighten screws (2) with 5 Nm + 1 Nm.
3. Plug on disk (6) and align.
4. Plug on igniter electrodes (3).
5. Install burner (refer to 9.2.3.2).
9.2.9 Flame Sensor, Replacement
9.2.9.1 Removal
1. Remove burner if required (refer to 9.2.3.1).
2. If required lever off igniter electrodes (Fig. 904) from
igniter box using screw driver and remove.
3. Remove disk (6).
4. Remove screw (14) and lock washer.
5. Withdraw flame sensor (15) and remove.
6. Perform procedures on components after
disassembly (refer to 9.1.1).
9.2.9.2 Installation
1. Position flame sensor (15, Fig. 904) for installation,
plug on to make correct electrical connections and
secure with screw (14) and lock washer.
2. Tighten screw (14) with 5 Nm + 1 Nm.
3. Plug on disk (6) and align.
4. Plug on igniter electrodes (3).
5. Install burner (refer to 9.2.3.2).
Fig. 904 Igniter Box and Flame Sensor, Replacement (Sheet 1 of 2)
Igniter box
Igniter electrodes
Removal and
installation of
igniter electrodes
Flame sensor
Summary of Contents for thermo 231
Page 2: ......
Page 10: ...1 Introduction Thermo 230 231 300 301 350 104 Page empty for notes...
Page 26: ...4 Technical Data Thermo 230 231 300 301 350 404...
Page 50: ...7 Circuit Diagrams Thermo 230 231 300 301 350 712...
Page 72: ...10 Packaging Storage Shipping Thermo 230 231 300 301 350 1002 Page empty for notes...
Page 73: ...Thermo 230 231 300 301 350 Annex A A 1 Annex A Scheduled Maintenance...