k^sfd^q u jh N
MRSPQPLc
`çåÑáÖìê~íáçå=jÉåì=J=pÉêîáÅÉ=pÉíìé=N
UJNV
olq=cfiqbo
Settings:
(contd.)
pmbba=j^u=EëéÉÉÇ=ã~ñáãìãF
maximum speed value: - 99.9 – + 99.9 kn (default = 30.0 kn)
The maximum speed value determines the upper limit of
the valid speed range. Actual speeds above the limit will be
rejected. Should the actual speed remain above the limit for
more than 10 s, a “speed invalid” alarm will be given.
The ROT filter sets a time constant for the serial ROT outputs.
Settings:
qfjb=`lkpqW=clo=pbof^i=olq=lrqmrqp
time constant: 0,00 – 9,99 s
(default value is 0,00 = no correction)
The time constant for serial ROT outputs can be selected
between 0,00 and 9,99 sec.
Typical values for the ROT filter time constant are generally
between 2 to 4 sec.