SURVIVAIR Opti-Fit
™
Convertible Facepiece
13
Figure 9a. Properly Center Head Strap Hub
Figure 9b. Properly Fitted Headnet
3. Fit Check Instructions for APR Configuration
You must perform the following fit check each time
the respirator is worn or before entering the contami-
nated area.
WARNING
If a leak-tight seal is not obtained during
the following fit check, do not wear the
respirator. Ask your supervisor or safety
professional for assistance. The failure
to comply with this warning may lead to
personal injury, illness, or death.
Negative Pressure Fit Check
Cover the inlet of the cartridges and/or filters with the
palms of your hands or another suitable item, such
as a thin sheet of plastic or rubber. When the respi-
rator is equipped with cartridges, filter retainers may
be used as an aid. Alternatively, the cartridges may
be removed to perform the fit check. If removed,
SPERIAN recommends someone other than you
reinstall them after a leak-tight fit is achieved. It
is difficult for the wearer to reinstall the cartridges
without disturbing the face seal and to determine
whether the cartridges are correctly seated against
the facepiece. It is your responsibility to ensure that
the face seal is not disturbed when reinstalling the
cartridges and that each cartridge is sealed against
the facepiece.
Inhale gently and hold your breath to slightly collapse
the facepiece. If air leakage occurs, readjust the
facepiece and head strap, then retest. If filter retain
-
ers are used, do not remove them after the fit check
is completed. Removing the filter retainers may shift
the facepiece and break the face seal.
4. How to Use the Respirator
To receive the maximum protection available from
your respirator, you must read, understand, and
follow all the warnings, limitations, and instructions
contained in this manual and follow your employer’s
instructions on the use and maintenance of the res-
pirator. Read and understand the following warnings
prior to using the respirator.
WARNING
● Never remove the respirator for any
reason while in the work area.
● You must leave the work area imme
-
diately if the facepiece-to-face seal is
disturbed for any reason such as:
a. Slippage due to sweating or ex-
cessive head movement.
b. The facepiece becomes dislodged
as a result of being knocked.
c. Sneezing or coughing while wear
-
ing the facepiece.
d. You need to blow your nose,
scratch your face or adjust your
spectacles.
● For any other reason that would cause
the facepiece seal to be disturbed.
● You must restore the facepiece-to-
face seal and perform a fit check in
a non-hazardous environment before
re-entering the work area.
● Failure to comply with this warning
may lead to personal injury, illness,
or death.
5. Doffing Instructions for APR Configuration
1. Loosen the two lower head straps completely
(for five strap head harness or Headnet).
2. Grasp the nozzle firmly, and pull the facepiece
upward over the head.
6. Chemical and Particulate Filter Service Life
and Replacement
a. Chemical Cartridge Service Life and Replacement