4
Safety in Action
SPERIAN FALL PROTECTION Deutschland GmbH & Co. KG, D-95015 Hof-Bavaria, P. O. B. 16 46, Phone +49/92 81/83 02-0, Fax +49/92 81/36 26, www.fall-protection.com
A 13. Working temperature –40 °C to +100°C; here, ensure that the system is free of grease, oil and
ice.
A 14. The operator must be in good health and must not be under the influence of alcohol, drugs or
medicines.
A 15.In case of the use of further personal protective equipment, relevant instructions must be
followed.
A 16.The check list (see Section G) must be fully and correctly compiled by the senior engineer of the
installing company using of an indelible pen.
A 17.With a weight of 100 kg and fall factor 2 situation (worst-case scenario) the
height required
under the feet of the user is at least 2 m.
A 18.
Note
The user may be not be sufficiently protected against hitting the ground or obstacles if at a
height of less than 2 m.
A 19.
Important!
Before using the safe-climbing system, ensure that there is the required free space of 2.0 m
under the user’s feet.
A 20. The system has been tested and approved by "Stelle 0158: DEKRA EXAM GmbH,
Dinnendahlstraße 9, 44809 Bochum.