background image

6

Safety in Action

SPERIAN FALL PROTECTION Deutschland GmbH & Co. KG, D-95015 Hof-Bavaria, P. O. B. 16 46,  Phone +49/92 81/83 02-0, Fax +49/92 81/36 26, www.fall-protection.com

Fig. B1

B 2.

Warning!

The cable end attachments must always be fastened to suitably-sized substructures.

B 3. The upper cable anchor point must always be above the user.

B 4.

Warning!

The cable must be sufficiently tensioned. The tension reading on the cable tensioner must
be between the minimum and the maximum marking.

B 5. The maximum distance between two intermediate brackets is 10 meter.

The intermeditate intermediate brackets reduce and limit the deflections of the steel
cable. The deflection of the system depends on the total length and the wind speed. The
intermediates must avoid that the cable is touching the construction and can get
damaged. 

1. 

Guided type fall arrester

     (24836 / 1017271)
2. 

Cable tensioner

     (24798 / 1017380)
     (24799 / 1017381)
3. 

Steel cable

4. 

Universal Beam bracket

     (24815 / 1017382)
     (24814 / 1017383)
5. 

Rung clamp

     (24807 / 1017384)
     (24806 / 1017385)
6. 

Manual intermediate

     (24838 / 1017370)
     (24839 / 1017373)
7. 

Automatic bracket

     (24840 / 1017375)
8. 

End piece of the cable

 

 

Summary of Contents for MILLER Soll Vi-Go

Page 1: ...with guided type fall arrester S ll Vi Go is personal protective equipment against falls from a height Guided type fall arrester including a rigid anchor line that complies with EN 353 Part 1 2002 Dat...

Page 2: ...e German Copyright Act Generalinformation These installation and usage instructions are applicable for the safety related components of the product The delivered product can differ from the version de...

Page 3: ...g to these instructions After use the fall arrester must not be left connected to the safe climbing system The fall arrester that comes with the Vi Go system must be operated only in original S ll Vi...

Page 4: ...llowed A 16 The check list see Section G must be fully and correctly compiled by the senior engineer of the installing company using of an indelible pen A 17 With a weight of 100 kg and fall factor 2...

Page 5: ...to be fixed is capable of withstanding loads resulting from a fall certificate for stability Aqualified engineer must certify this The maximum length of the cable may not exceed 200 m The following c...

Page 6: ...aximum marking B 5 The maximum distance between two intermediate brackets is 10 meter The intermeditate intermediate brackets reduce and limit the deflections of the steel cable The deflection of the...

Page 7: ...ll not touch the steel structure the maximum distance between the intermediates can be used B 6 At least the following components must be used when installing the Vi Go system 1 Cable tensioner 2 2 Ca...

Page 8: ...inst falls C 4 When working in or next to the ascent route and during jobs and actions that are not a part of the usual ascent and descent movements the climber must additionally secure themself with...

Page 9: ...chment point of the full body harness 4 Release the knurled bushing it locks automatically Fig C1 C 8 Danger An unsecured karabiner open knurled bushing is dangerous to human life C 9 The abdominal or...

Page 10: ...er 2 into the casing 3 Through the now open gap in the casing of the shuttle place the shuttle on the cable such that the arrow on the casing points upward 4 Release the slider 2 and the lock knob 1 5...

Page 11: ...n com C 12 Danger Fall protection must be ensured in another way before removing the fall arrester from the guide cable Removing from the guide cable 1 Press the lock knob 1 2 Press the lock knob 1 an...

Page 12: ...tent person for unimpaired condition to ensure it is in perfect working condition as required but at least once a year For reasons of safety the fall arrester may only be repaired by the manufacturer...

Page 13: ...e to the European standard Use only S ll Cable Information about permitted cables V Product code JJ construction year 0001 serial number monitoring testing institute advice to read the maintenance che...

Page 14: ...fall arrester that comes with the S ll Vi Go system should be washed with water and must be dried using a cloth Do not wash it with a quick cleaner thinner or degreaser containing trichloroethane Do n...

Page 15: ...15 Safety in Action SPERIANFALLPROTECTIONDeutschlandGmbH Co KG D 95015Hof Bavaria P O B 1646 Phone 49 9281 8302 0 Fax 49 9281 3626 www fall protection com Further Remarks...

Page 16: ...for regular inspections I for repair Year of manufacture Type designation Standard Date of purchase Serial number Date when used for the first time Date Reason for working on the system Damage determi...

Page 17: ...ks please cross yes no The fall arrester has been checked for perfect functioning The gap of the fall arrester is within the permissible range see Fig D1 The upper cable anchor point is always above t...

Page 18: ...Site Owner Street City Telephone Fax Manualhandedoverto name siteoperatororrepresentative signature Chief engineer of the installing company name signature Place Date Nextinspection at in 1 year Insta...

Reviews: