background image

PB

20

WARRANTY 

Sper Scientific warrants this product against defects in materials 

and workmanship for a period of

 five (5) years

 from the date 

of purchase, and agrees to repair or replace any defective unit 

without charge. If your model has since been discontinued, an 

equivalent Sper Scientific product will be substituted if available. 

This warranty does not cover probes, batteries, battery leakage, 

or damage resulting from accident, tampering, misuse, or abuse of 

the product. Opening the meter to expose its electronics will break 

the waterproof seal and void the warranty. 

To obtain warranty service, ship the unit postage prepaid to: 

SPER SCIENTIFIC LTD.

8281 East Evans Road, Suite #103

Scottsdale, AZ  85260

The defective unit must be accompanied by a description of the 

problem and your return address. Register your product online at 

www.sperwarranty.com within 10 days of purchase.

Rev 2/22/2018

Summary of Contents for AquaShock Bluetooth pH Kit 850057K

Page 1: ...AquaShock Bluetooth pH Kit 850057K ...

Page 2: ...ge and retrieval system without the express permission from Sper Scientific EPA Equivalency Method with Glass Probe 150 1 FCC ID 2AK5U 1300 This device and enclosed comply with part 15 of the FCC Rules Operation is subject to the two following conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause un...

Page 3: ...EATURES 5 MATERIALS SUPPLIED 5 LCD DISPLAY 6 POWER SUPPLY 7 KEYPAD 8 SETUP MODE 9 CALIBRATION 11 MEASUREMENT PROCEDURES 12 BLUETOOTH DATALOGGING 14 OPTIONAL ACCESSORIES 14 SPECIFICATIONS 15 WARRANTY 16 TABLE OF CONTENTS ...

Page 4: ...ation calibrates up to five points with auto recognition technology Data can be stored in the meter and later streamed to the included software for graphing manipulation and sharing via Bluetooth technology It can also stream in real time allowing users to wirelessly collect data from up to 100 feet away Data gathered with the AquaShock is precise fast and secure making it possible for the same me...

Page 5: ... screen Reads pH and mV Automatic or manual temperature compensation Automatic buffer recognition Celsius or Fahrenheit selectable 99 data points for analysis Calibration point review Internal clock and calendar Maximum minimum and average Hold function Low battery indicator Backlight MATERIALS SUPPLIED Meter Bluetooth Dongle Dual pH ATC Probe pH Buffers Distilled Water 1 Lithium 1450 mAh 7 4 V Ba...

Page 6: ...ale Unit Current measurement scale unit 4 Measuring Results Current measurement value 5 ATC MTC Automatic Manual Temperature Compensation indicator 6 Temperature Scale Current temperature measurement unit 7 Temperature Value Current temperature measurement value 8 Battery Icon Current battery power level 1 2 3 4 5 6 7 8 LCD DISPLAY ...

Page 7: ... charged More than 90 life remaining More than 85 90 life remaining More than 80 85 life remaining Less than 80 life remaining Probe Life Icon LCD DISPLAY POWER SUPPLY This meter is powered by one rechargeable Lithium 7 4V 1450 mAh battery The DC power adapter can be used to charge the battery even when the meter is turned off This meter includes a charge protection function and will automatically...

Page 8: ...ttery Power on off Backlight on off 2 Setup Setting parameters Confirm setting 3 MI Store data 4 MR Recall data 5 Max Min Ave Max Min Ave 6 Range Temp Switch measuring scale Set temperature value 7 Hold Exit Hold Exit 8 CAL Calibration 1 3 5 7 4 6 8 2 KEYPAD ...

Page 9: ...ode 6 Press EXIT to return to Normal Mode without saving the selection Real Time Clock 1 Press SETUP to enter the Setup Mode 2 Press or to select the Set Clock screen 3 Press SETUP to set the year The value will flash on the LCD 4 Press to increase the value by 1 Hold down to continually increase the value Press to decrease the value by 1 Hold down to continually decrease the value Press SETUP to ...

Page 10: ...Press EXIT to return to Normal Mode without saving View Calibration Data 1 Press SETUP to enter the Setup Mode 2 Press or to select the View CAL Data screen 3 Press SETUP to enter the mode 4 Press to view the previous calibration point Press to view the next calibration point The date and time is on cyclical display 5 Press EXIT to return to Normal Mode View Probe Parameters 1 Press SETUP to enter...

Page 11: ...All other keys will be inoperable while using the calibration function Calibrate Without Temperature Sensor MTC pH Probe 1 Press CAL for 2 seconds to enter Temperature Setup Mode The temperature value will flash on the LCD 2 Press to increase the value Hold down to continually increase the value Press to decrease the value Hold down to continually decrease the value For C the range is 0 to 60 0 C ...

Page 12: ... temperature 1 From Normal Mode press RANGE for 2 seconds to enter Set Temperature Mode The temperature value will flash on the LCD 2 Press to increase the value Press and hold to increase the value continuously Press to decrease the value Press and hold to decrease the value continuously For C the range is 0 to 60 0 C for F the range is 32 to 140 0 F 3 Press SETUP to save and the meter returns to...

Page 13: ...GE to select the scale 2 Press MAX MIN AVE the maximum recorded value will appear on the LCD The date and time is on cyclical display 3 Press MAX MIN AVE the minimum recorded value will appear on the LCD The date and time is on cyclical display 4 Press MAX MIN AVE the average recorded value will appear on the LCD The date and time is on cyclical display 5 Press MAX MIN AVE to return to Normal Mode...

Page 14: ... Turn the meter on and Press the yellow SETUP button to enter SETUP mode 4 Using the UP and DOWN arrows scroll through the functions until BLUETOOTH Setting Appears on the LCD screen 5 Press the yellow SETUP button to enter this feature Use the UP and DOWN arrows until YES appears on the screen Press the yellow SETUP button once to confirm The meter will return to normal measuring mode and you wil...

Page 15: ...hand corner See Image 2 below 2 A pop up window will open Choose your desired meter from the AquaShock choices and click OK Note All connected Bluetooth devices will show in the popup window including non AquaShock devices 3 The software will now display the Workstation See image 3 ...

Page 16: ...lue from the meter See image 4 Press STOP to stop the live stream The data can now be Exported to Excel Downloading Internal Memory Points 1 Click the LOAD data button on the upper left hand side of the Workstation 2 All Internal memory points gathered through the MI function will load in the lower left quadrant of the Workstation See Image 5 ...

Page 17: ... from internal memory If you are downloading both a stream and a set of internal memory points you must export them individually 1 Click the LOAD data button on the upper left hand side of the Workstation 2 Choose your save location from the Save As popup window 3 Your data is now available as an Excel file ...

Page 18: ...016 Standard pH Probe non ATC 840049 Spear Tip pH Probe non ATC 840093 Field Tripod 860008 pH 4 Buffer Solution 3 bottles of 40ml each 860009 pH 7 Buffer Solution 3 bottles of 40ml each 860010 pH 10 Buffer Solution 3 bottles of 40ml each 860011 Deionized Water 3 bottles of 40ml each 860012 pH Buffer Set 1 each pH 4 7 10 ...

Page 19: ... pH 0 1 F 0 1 C 0 1 mV Accuracy 0 01 pH 0 9 F 0 5 C 0 3 mV Input BNC Connector Temperature Probe Connector BNC Connector Calibration Up to 5 points Memory Up to 99 data points pH Slope Range 75 to 110 Temp Compensation Automatic ATC or manual MTC from 32 to 140 F or 0 to 60 C Operating Temp 32 to 122 F 0 to 50 C Battery Lithium battery 7 4 V 1450 mA h Battery Life 200 hours Bluetooth Range 100 fee...

Page 20: ...ty does not cover probes batteries battery leakage or damage resulting from accident tampering misuse or abuse of the product Opening the meter to expose its electronics will break the waterproof seal and void the warranty To obtain warranty service ship the unit postage prepaid to SPER SCIENTIFIC LTD 8281 East Evans Road Suite 103 Scottsdale AZ 85260 The defective unit must be accompanied by a de...