background image

10

11

PC CONNECTION

System Requirements

Windows NT 4.0/ NT2000/ XP/ VISTA

Minimum Hardware Requirements

PC or Notebook with Pentium 90 MHz or higher, 32 MB RAM; At least 

50 MB hard disk space available to install the software. Recommended 

resolution of 800 x 600. 

Installing the Software
Note…

 

Different computer systems may require slightly different installation steps 

than those below. 

1.  The first most important step in software installation is to verify that 

the target system meets the general hardware requirements of the 

application. Beginning the installation in a computer machine which 

does not possess the minimum requirements can lead to either an 

unsuccessful installation or failure of the program to run after installing it.

2.  Since programs in general are written to be Operating System 

dependent, make sure that the version of the application you are installing 

corresponds to the Operating System platform running on your machine.

3.  Aside from the general hardware requirements, some computer programs 

also have software requirements prior to installation. Double check if you 

need to update or upgrade your Operating System or if there is a need to 

download other tools or utilities.

4.  Once all the initial requirements have been met, make sure that there 

are no unnecessary programs running before beginning the installation 

procedure. In some instances, applications may require that the antivirus 

programs be disabled. Make sure that you are installing a legitimate 

application before disabling your protection software.

5.  Software installation can be done either from the Internet (skip to step 

8) or from an installation disc provided by the software manufacturer. 

To install from the disc, simply open the CD or DVD drive and insert 

the installer.

6.  A setup wizard window should be launched. In case there is none, open 

the Explorer and navigate to the optical drive. Double click on either the 

Autorun or Setup file.

Summary of Contents for 850013

Page 1: ...Advanced Datalogging Sound Meter 850013 Instruction Manual...

Page 2: ...other means that do not yet exist or may be developed including photocopying recording or any information storage and retrieval system without the express permission from Sper Scientific INTRODUCTION...

Page 3: ...measurements in science and engineering the decibel is most commonly recognized as a measure of the intensity of a sound wave The decibel is a unit of power ratio with the number of units equal to a...

Page 4: ...battery power is almost empty the empty battery symbol will disappear from the LCD Press MEM or REC Lo Bat appears on the LCD If the meter is in recording mode it will stop recording For battery repl...

Page 5: ...utton 13 Battery compartment on back 14 A C Sets frequency rating to A or C scale 15 CAL potentiometer Calibration control for level calibration adjustment 16 External DC 9V power supply jack Connect...

Page 6: ...ttery fluid leakage After reinstalling the batteries set the date and time CALIBRATION The meter has been factory calibrated Annual calibration is recommended for best results 1 Prepare for calibratio...

Page 7: ...N MAX again to view the minimum 4 To exit this mode and clear all maximum and minimum values press and hold MIN MAX until MAX MIN disappears from the display Note Maximum and minimum values cannot be...

Page 8: ...RECALL press and release POWER CLr appears on the LCD The LCD displays SURE 5 4 3 2 1 0 The meter allows 5 seconds to abort the operation by releasing RECALL Continue holding RECALL until the meter r...

Page 9: ...her applications Close other applications If the problem is still not resolved restart the computer and run the software again 2 Saving the graph to a file that can be used in Excel When saving the gr...

Page 10: ...nstalling corresponds to the Operating System platform running on your machine 3 Aside from the general hardware requirements some computer programs also have software requirements prior to installati...

Page 11: ...n completed and the setup wizard has terminated reboot your machine before launching the newly installed software Main Menu File_Open Retrieves files from the disk File_Save Saves the active window th...

Page 12: ...en selected the mouse cursor will become a cross sign when moving through the graph Click on the graph to mark a cross sign on the graph When selected the mouse cursor will become a I sign text tool w...

Page 13: ...al time graph is not allowed to open the popup menu To zoom in on the graph using the mouse Click the left mouse button and drag the cursor to select the new graph boundaries Release the mouse button...

Page 14: ...icon from the tool bar 3 The save dialog window appears on the screen Select the file name and file type to save Note There are three file type options binary ghf text txt and Excel format csv Of the...

Page 15: ...OVER indicates that the input is over the upper range limit UNDER indicates that the input is less than the lower range limit Datalogging capacity 31 000 records Operating temperature 0 to 40 C 32 to...

Page 16: ...y does not cover probes batteries battery leakage or damage resulting from accident tampering misuse or abuse of the product Opening the meter to expose its electronics will break the waterproof seal...

Reviews: