background image

MULTI-FUNCTION DIGITAL 

RADIATION DETECTOR

840023

Summary of Contents for 840023

Page 1: ...MULTI FUNCTION DIGITAL RADIATION DETECTOR 840023 ...

Page 2: ...ion data transmission and powerful software for data evaluation It can detect a β y and X ray It also can detect radiation pulse times This meter can be widely used in pharmaceutical factory s laboratory s power stations stone pits emergency rescue stations metal plants oil fields and the oil pipelines environmental protections police depart ments and etc This meter can detect Groundwater radium p...

Page 3: ... confirm button 9 ESC exit button in any setting or mea suring conditions press this button can return to Setup state 10 Power consumption measurement of batter and parameter setting up key 11 SV unit accumulating count key and timing measuring key 12 CPS CPM pulse counting measurement unit switch button 4 4 LCD display symbol description 1 Boot nuclear radiation ray measuring dynamic icon indicat...

Page 4: ...European CE US FCC 15 Warranty One year for the main engine 6 7 Note Sievert mark is Sv unit 1Sv 100 rem rem roentgen equivalent man µSv h unit of ray radiation dose rate 1SV 100Rem 1 rem 1cSv 10mSv 1uR h 10uSv h 1 mR h 10mSv h CPS pulse times per second In the pulse rate model pulse has constantly been measured by counter tube and translated into pulse rate CPM pulse counts per minute ln the puls...

Page 5: ...on The digital nuclear radiation scanner could also do the measure ment recording the accumulated radiation dose at specific time The initial unit is µSv and it will automatically convert to mSv or Sv as the measured dose rate getting higher 6 5 Button for Dose Rate accumulation 1 Press SV button and enter into the regular infinite dose rate accumulation calculation mode with dose rate icon µSv on...

Page 6: ...into timing pulse counting mode and shows 10 the pulse and timing flashing icon on display press this button again to stop pulse counting pressing once again will return to CPS pulse counting function 3 Long press CPS CPM button for two seconds or under pulse measurement mode and will enter into measuring time setup mode and the screen shows pulse and time icon At this time the dis play shows thre...

Page 7: ... method of DATE setup as above hour minute second 12 6 11 Alarm Threshold Value Setup default value is 205uSv h 1 Press SETUP button once then select ALM BL icon through UP or DOWN button Then the ALM icon will flash press EN TER button to confirm your option and press ENTER button once again to set the single digit ten digit and hundred digit The related digit will flash and can be adjusted by pr...

Page 8: ...cally record the measure ment data during the transmission For the connection with PC pis refer to the software operation instruction 7 Battery Voltage Detection function 1 The multi function digital nuclear radiation scanner uses sup per powerful Lithium battery Press UP or BATTERY DETECTION button it will display the inter nal battery voltage normal voltage is 2 7V to 3 7V 2 Press ESC button to ...

Page 9: ...ble This warranty does not cover probes batteries battery leakage or damage resulting from accident tampering misuse or abuse of the product Opening the meter to expose its electronics will void the warranty To obtain warranty service ship the unit postage prepaid to SPER SCIENTIFIC LTD 8281 E Evans Rd Suite 103 Scottsdale AZ 85260 The defective unit must be accompanied by a description of the pro...

Reviews: