3rd BYTE:

bit7

bit6

bit5 bit4 bit3

bit2

bit1

bit0

Auto Power Off

Memory Full

Resolution

Sign

OL

bit0: 

1→main window value is OL, 0→not OL

 

bit1:

 1→main window value is minus, 0→main window value is plus.

 

bit2:

  1→4th byte and 5th byte represent #### , 0→4th byte and 

 

5th byte represent ###.#

bit6:

 1→Memory is full. 0→Memory is not full.

 

bit7:

 1→Auto power off enabled. 0→Auto power off disabled.

Setup ThermoLog (Thermo DataLogger)— 

RS232 interface software:

The ThermoLog package contains:

 

• Two 3.5” diskettes

 

• Custom designed RS232 cable for THERMOLOG.
System Required:
• Windows 95 or Windows 98 or Windows NT 4.0 above.
Minimum Hardware Required:

•  486-100 MHz PC compatible, 16 MB RAM; At least 5 MB 

hard disk space available to install THERMOLOG program. 

Recommended display resolution is 800X600.

4th BYTE:

first two BCD code of main window value.

5th BYTE:

last two BCD code of main window value

6th BYTE:

BCD code of month.

7th BYTE:

BCD code of day.

8th BYTE:

BCD code of hours.

9th BYTE:

BCD code of minute.

10th BYTE:

 

End byte, its value is 3, 1st and 10th are used  

to check frame error.

Summary of Contents for 80008

Page 1: ...Advanced Datalogging Thermometer 800008 Instruction Manual...

Page 2: ...any means electronic mechanical or other means that do not yet exist or may be developed including photocopying recording or any information storage and retrieval system without the express permissio...

Page 3: ...ock functions and a low battery indicator An RS232 interface allows the unit to communicate with a computer Applications include HVAC lab work environmental work process control and the food industry...

Page 4: ...he thermocouple plug into the meter 3 The meter will default to the temperature scale last used Press the C F button to change the temperature scale if necessary 4 Begin taking temperature readings 5...

Page 5: ...t press the HOLD button again Setting the Recording Interval for Datalogging 1 With the meter turned off press and hold the MAX MIN button 2 Press the POWER button to turn the meter on Release the but...

Page 6: ...NT The low battery indicator appears when the battery needs replacement Insert a fresh 9V battery PC CONNECTION The Digital Output is a 9600bps N 81 serial interface The RX is a 5V normal high input p...

Page 7: ...s For example when sending command K to meter it will return 3 0 5 ASCII 13 Command U Return 32768 bytes Command P Instead of returning all 32768 bytes it only returns recorded data Command H Equivale...

Page 8: ...software The ThermoLog package contains Two 3 5 diskettes Custom designed RS232 cable for THERMOLOG System Required Windows 95 or Windows 98 or Windows NT 4 0 above Minimum Hardware Required 486 100...

Page 9: ...irectly available to download due to it must be purchased If you find that the software you need is not available please contact our Customer Support at 480 948 4448 or email info sperscientific com f...

Page 10: ...DataLogger Window the user can load the recorded data from the thermometer Tabular By opening the Tabular window the present data from the thermometer will be listed in a scrolling table These data c...

Page 11: ...add the following tolerance into the accuracy spec 0 01 of reading 0 03 C 0 01 of reading 0 06 F Probe Temp Range 50 to 300 C 58 to 572 Numerical Display 4 digital Liquid Crystal Display Input Projec...

Page 12: ...does not cover probes batteries battery leakage or damage resulting from accident tampering misuse or abuse of the product Opening the meter to expose its electronics will break the waterproof seal an...

Reviews: