SPECIFICATIONS

Range

Resolution

Accuracy

-200°C to 200°C    

0.1°C

±(0.2% r 1°C)

200°C to 400°C    

1°C

±(0.5% r 1°C)

400°C to -1370°C    

1°C

±(0.2% r 1°C)

-328°F to -200°F    

1°F

±(0.5% r 2°F)

-200°F to 200°F    

0.1°F

±(0.2% r 2°F)

200°F to 2498°F    

1°F

±(0.3% r 2°F)

Temperature Coefficient: 

 

For ambient temperatures from 0°C to 18°C and 28°C to 50°C, for each  

°C ambient below 18°C or above 28°C add the following tolerance into the  

accuracy spec: 0.01% of r 0.03°C (0.01% of r 0.06°F)

Probe Temp Range

-50 to 300ºC (-58 to 572º)

Numerical Display:

4 digital Liquid Crystal Display

Input Projection at  

Thermocouple Input: 

60V DC or 24 Vrms AC

Operating Environment: 0°C to 50°C (32°F to 122°F); 0 to 80% RH
Storage Environment:

10°C to 60°C (14°F to 140°F); 0 to 80% RH

Storage Altitude

 ≤ 2000 meters

Power Requirement: 

9 Volt Battery, NEDA 1604 or JIS 006P  

or IEC6F22

Battery Life: 

Approx. 100 hrs. with alkaline battery

AC Adapter: 

9V DC ±15%  100 mA

Dimensions

7¼" × 2½" × 1¼" (184 × 64 × 32 mm)

Weight

7.4 oz (210 g)

Summary of Contents for 80008

Page 1: ...Advanced Datalogging Thermometer 800008 Instruction Manual...

Page 2: ...any means electronic mechanical or other means that do not yet exist or may be developed including photocopying recording or any information storage and retrieval system without the express permissio...

Page 3: ...ock functions and a low battery indicator An RS232 interface allows the unit to communicate with a computer Applications include HVAC lab work environmental work process control and the food industry...

Page 4: ...he thermocouple plug into the meter 3 The meter will default to the temperature scale last used Press the C F button to change the temperature scale if necessary 4 Begin taking temperature readings 5...

Page 5: ...t press the HOLD button again Setting the Recording Interval for Datalogging 1 With the meter turned off press and hold the MAX MIN button 2 Press the POWER button to turn the meter on Release the but...

Page 6: ...NT The low battery indicator appears when the battery needs replacement Insert a fresh 9V battery PC CONNECTION The Digital Output is a 9600bps N 81 serial interface The RX is a 5V normal high input p...

Page 7: ...s For example when sending command K to meter it will return 3 0 5 ASCII 13 Command U Return 32768 bytes Command P Instead of returning all 32768 bytes it only returns recorded data Command H Equivale...

Page 8: ...software The ThermoLog package contains Two 3 5 diskettes Custom designed RS232 cable for THERMOLOG System Required Windows 95 or Windows 98 or Windows NT 4 0 above Minimum Hardware Required 486 100...

Page 9: ...irectly available to download due to it must be purchased If you find that the software you need is not available please contact our Customer Support at 480 948 4448 or email info sperscientific com f...

Page 10: ...DataLogger Window the user can load the recorded data from the thermometer Tabular By opening the Tabular window the present data from the thermometer will be listed in a scrolling table These data c...

Page 11: ...add the following tolerance into the accuracy spec 0 01 of reading 0 03 C 0 01 of reading 0 06 F Probe Temp Range 50 to 300 C 58 to 572 Numerical Display 4 digital Liquid Crystal Display Input Projec...

Page 12: ...does not cover probes batteries battery leakage or damage resulting from accident tampering misuse or abuse of the product Opening the meter to expose its electronics will break the waterproof seal an...

Reviews: