118150-001 REV. B
Page 52 of 66
4.15.2 Set MA <11>
Description:
The host requests that the firmware change the MA set point.
Direction:
Host to supply
Syntax:
<STX><11><,><ARG><,><ETX>
Where:
<ARG> = Value of mA in ASCII format. Units are micro amps. Example,
For 0.2 mA, enter 200.
Example:
<STX>11,200,<ETX>
Response:
<STX><11><,><$><,><ETX> or
<STX><11><,><ARG><,><ETX>
where <ARG> = error code
Error Codes: 1 = receive error, 2 = unrecognized command