EPM/SMS MANUAL
6
118026-001 REV K
2.3 Installation Instructions
The following are installation instructions for the below
listed models. They are approved in accordance with
EN60950:1993/AM1:1993/AM2:1993
and
EN61010-
1:1993. If installed in information technology equipment,
the installation must comply with the above standard.
•
The unit must be fused by an external 5A fuse.
•
The unit is convection cooled.
•
The maximum permitted temperature of the air
surrounding the power supply is 40ºC.
•
The chassis of the power supply should be suitably
connected to Protective Earth.
Model
Output Voltage
Output Power
SMS20X60
20kV/3mA
60W
SMS30X60
30kV/2mA
60W
SMS40X60
40kV/1.5mA
60W
SMS50X60
50kV/1.2mA
60W
SMS60X60
60kV/1mA
60W
Table 2.1
Output Voltage and Current Ratings for
24Vdc or 28Vdc /5A Models
Dieses Geraet ist zugelassen gemaess
EN60950:1993/AM1:1993/AM2:1993 and EN61010-
1:1993. Im falle das diesses Geraet in
Informationstechnik-einrichtung eingegaut werden soll,
die installation muss gemaess den obengenannten Norn
erfolgen.
•
Das Garaet muss externe fliken Sicherungen
Gesichert sein: 5A
•
Kuehlung ohne Luefter.
•
Maximale zugelassene Lufttemperature un den
Schaltnetsteil: 40ºC.
•
Eine angemessene Verbindung zwischen den
Metallrahmen des Netzteiles und Schutzerde muss
erstellt stein.
Model
Ausgaenge
Output Power
SMS20X60
20kV/3mA
60W
SMS30X60
30kV/2mA
60W
SMS40X60
40kV/1.5mA
60W
SMS50X60
50kV/1.2mA
60W
SMS60X60
60kV/1mA
60W
Table 2.1
Nennwerte
24Vdc oder 28Vdc /5A