DX
FUNCTION
SYSTEM
DEFINITION
DEFAULT
SETTING
Heating
0
Pulse width modulation
D01
control
1
On-Off 0.5ºC +/- 0.25ºC
0
2
On-Off 1.0ºC +/- 0.5ºC
Room
-3.0ºC to
Temperature offset from
D02
temperature
3.0ºC
measured temperature to
0ºC
offset
compensate for any error
Sensor probe or
0
Sensor/Cylinder stat not connected
D03
cylinder thermostat
1
Sensor/Cylinder stat connected
0
connection
D03 must be set to 1 then external
Sensor probe
0
sensor be used as Air sensor. There
D04
used as air sensor
will be no internal temp measurement
or floor sensor
D03 must be set to 1 then external
0
1
sensor used for floor protection.
Internal temp is measured by stat
D05
Cooling control
1
On-Off 0.5ºC +/- 0.25ºC
2
2
On-Off 1.0ºC +/- 0.5ºC
D06
Actuator type
0
NO normally open
1
1
NC normally closed
D07
Valve protection
0
Disable
1
1
Enable
41
www.speedfitUFH.co.uk
Installation - Device Parameters