The washer is designed to be operated on a separate
branch, polarized, three-wire, effectively grounded,
120 Volt, 60 Hertz, AC (alternating current) circuit
protected by a
15 Amp fuse
, equivalent fusetron or
circuit breaker.
The three-prong grounding plug on the power cord
should be plugged directly into a polarized three-slot
effectively grounded receptacle rated 110/120 Volts
AC (alternating current) 15 Amps. Refer to
Figure 15
to determine correct polarity of the wall receptacle.
Grounding Information
The washer must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current.
The washer is equipped with a cord having an
equipment-grounding conductor and a 3-prong
grounding plug. The plug must be plugged into an
appropriate outlet that is properly installed and
grounded in accordance with all local codes and
ordinances.
Do not modify the plug provided with the washer - if it
will not fit the outlet, have a proper outlet installed by
a qualified electrician.
NOTE: Have a qualified electrician check the
polarity of the wall receptacle. If a voltage reading
is measured other than that in
Figure 15
, the
qualified electrician should correct the problem.
NOTE: The wiring diagram is located in the
control hood.
Step 8: Check Installation
Refer to
Installer Checklist
on the back cover of this
manual and make sure that washer is installed
correctly.
Run the washer with a test load to make sure it is
operating properly and is properly leveled.
1. Put about six pounds of laundry (four bath towels
and three jeans) into washer.
2. Close door.
3. Select a Spin Only cycle and press Start.
4. When washer spins at high speed, verify that it is
stable.
5. If it is not, after cycle is complete, refer to Step 2
and readjust leveling legs.
To reduce the risk of an electric shock or
fire, DO NOT use an extension cord or an
adapter to connect the washer to the
electric power source.
W082
WARNING
Improper connection of the equipment-
grounding conductor can result in a risk
of electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the washer is
properly grounded.
W216
WARNING
This unit is equipped with a three-prong
(grounding) plug for your protection
against shock hazard and should be
plugged directly into a properly grounded
three-prong receptacle. Do not cut or
remove the grounding prong from this
plug.
W213
WARNING
Summary of Contents for 802758R4