11
10
Spectrum
TM
14.
Once the values have been selected move to the next time slot by pressing the next ( ) button
Parameter
Option
Description
Volume of treated water
IF xx.x
Volume of water to be treated
IF-oF
Capacity / Hardness Mode
Parameter
Option
Description
Length of 1
st
cycle
1-xx
Length of cycle in minutes
Length of 2
nd
cycle
2-xx
Length of cycle in minutes
Length of 3
rd
cycle
3-xx
Length of cycle in minutes
Length of 4
th
cycle
4-xx
Length of cycle in minutes
This is the number of minutes per cycle of the regeneration process. The value in minutes can be found in the
‘Cycle
Time Table’
overleaf.
Parameter
Option
Description
1
st
regeneration time slot
xx:H1
Regeneration time
oF:H1
Regeneration time slot disabled
2
nd
regeneration time slot
xx:H2
Regeneration time
oF:H2
Regeneration time slot disabled
3
rd
regeneration time slot
xx:H3
Regeneration time
oF:H3
Regeneration time slot disabled
4
th
regeneration time slot
xx:H4
Regeneration time
oF:H4
Regeneration time slot disabled
7. Valve Programming Set-Up
Note: Some items may not be shown depending on valve configuration. The valve will discard any
changes and exit Master Programming Mode if any button is not pressed for sixty seconds.
This is the volume in cubic meters your system can soften. The capacity can be determined with the
‘Capacity
Calculation Table’
overleaf.
9.
Select the appropriate option press the next ( ) button
8.
Adjust the value using the up ( ) and down ( ) arrows.
10.
Adjust the values using the up ( ) and down ( ) arrows.
11.
Once the values have been selected move to the next cycle by pressing the next ( ) button
12.
You can choose up to 4 regeneration slots in
R-3
(delayed mode), allowing you to minimise the risk of hard
water after expiring capacity.
13.