9
8
Spectrum
TM
6. Installation Instructions
Install the pressure vessel with the valve in a convenient location. Ensure the floor under the brine tank is clear and flat.
Connect the brine tube to the valve on one side and to the safety brine valve included in the brine tank.
Use Teflon® tape if necessary in order to seal between the drain fitting and the outlet flow control.
6.3. Connecting
SPECTRUM 5 Valve
SPECTRUM 7 & 12 Valves
6.4. Start Up
1.
Half fill the brine tank with water.
2. Add salt until in total the brine tank is ¾ full.
3.
For systems with a by-pass feature, place in by-pass position (Fig 1.)
4. Turn on the main water supply.
5. Open a cold soft water tap nearby and allow to run for a few minutes or until the system is free from foreign material
that may have resulted from the installation.
6.
Once clean, close the water tap. Place the by-pass in service position and let water flow into the pressure vessel.
When water flow stops, slowly open a cold water tap nearby and allow to run until the air is purged from the unit.
7. Plug the valve to a power source.
8. Switch on the electrical power.
9. Once plugged the valve may do a cycle on its own in order to go to service position.
10.
Start a regeneration by pressing the [R] button on the controller to go through a first complete cycle in order to
initialise the system. This operation can last up to an hour.
Fig 1.
‘Service position’
shown.
Moving the red
lever upwards to
a vertical position
will put the valve
into the ‘Bypass
position’.