eLift Leg Troubleshooting Guide
0115700R2 Page 16 of 17
Symptom
Problem
Solution
eLift legs will not operate
Loss of power
Be sure unit is plugged into a live circuit.
Loose electrical connections
Make sure all electrical connections are securely plugged into the control box.
Object encountered under
worksurface
1. Raise the worksurface by pressing the “Up” button.
2. Remove any items sitting below the worksurface.
3. Reset the lift mechanism (see below for procedure.)
Misaligned actuators
Reset Procedure:
1. Unplug, then re-plug the power cord into a wall outlet.
2. Make sure all lift mechanism wire connections are in place and secure.
3. Remove anything located under the worksurface.
4. Press and hold the “Down” button to lower the worksurface to the lowest “work”
position until it stops moving.
5. Release the “Down” button.
6. Press and hold the “Down” button for 30 seconds. The worksurface will lower,
bottom-out, slightly rises, then stop moving. The worksurface must be completely
lowered before resuming operation.
Note: If the worksurface does not lower when doing this step, release the
“Down” button, and retry step 6.
7. Release the “Down” button. The lift mechanism has now been reset and the
worksurface can be adjusted normally.
This table has a load-sensing, anti-collision feature in the controller that actively locks out
the lift mechanism when unbalanced loads are encountered; i.e. weight from a person
sitting on one side of the table. The following reset procedure should be performed if the
lift mechanism becomes locked out and the table does not extend or retract.
WARNING
The anti-collision feature does not function in RESET MODE. Do not sit at,
under, or on the worksurface while resetting the lift mechanism. Be sure the
table movement does not interfere with objects or people. Do not place any
items under the worksurface.