Factory settings
on the CEREBRAL-55:
Output Voltage: V_set = 12V
Output Current: I_set = 2A (the minimum Current Limit value)
Output Current Ramping = Deactivated (displayed as 0, 1.0 A/s)
Configure
new V_set / I_set / Ramping settings through
Spectronik Cerebral DCDC GUI
.
V_set and I_set
are limited such that their product does
not exceed 5600W
.
This allows the full 5.5kW to the load end despite in-line voltage drops from conduction losses.
CHAPTER 2 | OVERVIEW
2
OVERVIEW
2.1 CEREBRAL-55 SYSTEM OVERVIEW
12
Off
On
1
2
3
4
6
7
8
9
10
11
13 14 15
ITEM DESCRIPTION
1.
Output On/Off Switch
6.
Control board
11.
Converter Board
2.
Programming Port
7.
Fans x3
12.
GND M5 stud
3.
Load VI sensing
8.
DCDC Converters x3
13.
V_in M5 stud
4.
Supply/Battery VI sensing
9.
Status LED
14.
V_out M5 stud
5.
UART Port
10.
Mounting M3 Spacers x10
15.
GND M5 stud
5