LED
Output
Critical Error Shutdowns
Identifications
GUI
notification message for Critical Error Shutdowns
An example:
The error code message
CHAPTER 5 | APPENDIX
5.5 APPENDIX – LED OUTPUTS AND CRITICAL ERROR SHUTDOWNS
Critical Error SHUTDOWN message
Corrective Action
Sys Over-Temperature SHUTDOWN
Check ventilation system/layout
Input Over-Voltage SHUTDOWN
Verify possible 90V exceedance at input
Input Under-Voltage SHUTDOWN
Check possible short-circuit at input
Input Over-Current SHUTDOWN
Verify that supply is adequate for load demand
Output Under-Voltage SHUTDOWN
Verify that supply is adequate for load demand
Output Over-Current SHUTDOWN
Check possible short-circuit at output
Critical Error SHUTDOWN message
LED
Power ON
Green
Short Blinking
In Operation
Green
Solid
High Temperature Warning
Orange
Long Blinking
Fan Tacho Lost
Red
Short Blinking
Critical Error SHUTDOWN
Red
Solid