Electrochemical heated-diode sensor
•
"No-reset" detection of CFCs, HCFCs, HFCs and HFOs
•
Automatic adjustment (zeroing) to refrigerants in leak test area
•
Rugged, flexible probe with a foam filter for sensor protection
•
High/Low leak sensitivity and ON/OFF in one switch
•
Variable-pitch audible leak signal
To get the best performance from your PRO-Alert™ Refrigerant Leak Detector, please read
this manual carefully before you start using it. If you have any questions or need
additional assistance, please call Spectronics Corporation's Customer Service Department
at 1-800-274-8888 (outside the USA and Canada, call 1-516-333-4840).
Specifications
Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Indoor or outdoor
Minimum sensitivity to R-12, R-22, R-134a and R-1234yf . . . . . . . . . . . .0.25 oz/yr (7 g/yr)
Operating temperature range . . . . . . . . . . . . . . . . . . . . -15°F to 122°F (-27°C to 50°C)
1
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . .14°F to 140°F (-10°C to 60°C)
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95% RH NC Max.
Altitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6500 ft (2000 m)
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Two "D" cell alkaline batteries
Battery life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Approximately 16 hours
Pollution degree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Overvoltage category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Weight (with power cells) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.3 lb (0.58 kg)
1
May be operated for a limited time in lower temperature environments.
Getting Started
1. Install the batteries and sensor as described below.
2. Press the control button to power on the PRO-Alert.
3. Wait for the PRO-Alert to warm up. All three LEDs will illuminate during warm up.
When the High sensitivity LED starts flashing and a chirping sound is heard, the
PRO-Alert is ready to find leaks.
4. Begin checking for leaks.
The PRO-Alert™ Refrigerant Leak Detector provides similar responses to all CFCs,
HCFCs, HFCs, HFOs and refrigerant blends (e.g. R-404A and R-407c) as well as SF6.
There is no need to select the refrigerant you are working with.
How to Install the Alkaline Batteries
1. Remove the battery cover by releasing the latch and sliding the cover down and off
the handle.
2. Install two "D" size alkaline batteries as shown in Figure 1.
3. Reinstall the battery cover by aligning it with the handle and sliding it up until the latch
engages.
When the batteries reach the end of their life, the green Low Battery indicator illuminates
and will start flashing. While the batteries may operate the PRO-Alert™ up to a period of
one hour after the Low Battery indicator illuminates, the batteries should be replaced as
quickly as possible.
Summary of Contents for Pro Alert TP-9360
Page 1: ...1 OPERATING MANUAL TP 9360 4 22 AM06026ML 7 Printed in U S A ENG 1 FR 8 DE 24 ES 16 ...
Page 8: ...8 TP 9360 Français ENG 1 FR 8 DE 24 ES 16 MANUEL D UTILISATION ...
Page 16: ...16 TP 9360 Español ENG 1 FR 8 DE 24 ES 16 MANUAL DE INSTRUCCIONES ...
Page 24: ...24 TP 9360 Deutsche ENG 1 FR 8 DE 24 ES 16 BENUTZERHANDBUCH ...
Page 32: ...32 ...