3.  STARLPRO-1500 SPECIFICATIONS 

See 

http://www.spectratime.com/documents/iSource_StarLPRO-1500_spec_031212.pdf

 

4.  STARLPRO-1500 INSTALLATION AND OPERATION 

4.1 

INTRODUCTION 

This  chapter  of  the  manual  contains  information  regarding  the  installation  and  operation  of  the  SpT  Model 
STARLPRO-1500. It is recommended to read this chapter carefully prior to operate the unit. 
 

4.2 

SHIPPING AND RECEIVING INFORMATION 

The  STARLPRO-1500  is  packaged  and  shipped  in  a  foam-lined  box.  The  unit  is  inspected  mechanically  and 
electrically prior to shipment. Upon receipt of the unit, a thorough inspection should be made to ensure that no 
damage has occurred during shipping. If any damage is discovered, please contact 
 
Orolia Switzerland SA / Spectratime  
PHONE: +41 32 732 16 66 
FAX: +41 32 732 16 67 
CH-2000 NEUCHATEL / SWITZERLAND 
 
Should it be necessary to ship the unit back, the original case and packing should be used. If the original case 
is not available, a suitable container with foam-packing is recommended. 
 
 

CAUTION 

Care  must  be  taken  for  the  transportation  of  the  STARLPRO-1500  to  ensure  that  the  maximum 
acceleration due to a shocks 50g/ 11ms is not exceeded. 
 
STARLPRO-1500 contains glass bulbs, crystal resonators and crystal filters. 
 
When  STARLPRO-1500  integrated  into  an  instrument,  such  instrument  shall  be  packed  in  a 
suitable  container,  similar  to  containers  generally  use  for  the  transportation  of  instruments  like 
scope, video display or computer. 
 

 

4.3 

MOUNTING 

The unit should be mounted in preference to a metallic plate or metallic chassis. Mounting screws (6 x UNC-4-
40)  or  (  M3  with  option  code  ‘M3’)  ,  stainless  steel  5mm  maxi  into  the  STARLPRO-1500  box)  should  be 
tightened with a torque between 50 Ncm and 100 Ncm. 
 
The  heat transfer  characteristics  of  the mounting  surface must  be  adequate  to  limit  the  rise  of the  unit's  base 
plate to <+60°C. Since the minimum total power consumption for proper Rb operation is around 200mA / 24V, 
the allowable environmental temperature (Tamax), for this mounting is: 
 
Tamax = 60°C -Vs x Is x Rk 
 
 

CAUTION 

Care must be taken to ensure that the maximum operating temperature 
is not exceeded, (+60°C as measured at the unit's base plate) 
 
This maximum temperature can be reached when operating the unit into forced air flow at 60°C or by 
mounting the unit into user equipment with thermal interface corresponding to a thermal resistance of 
1 to 2 °C/W between the STARLPRO-1500 unit and the ambient . 

 
 

Summary of Contents for iSource Plus StarLPRO-1500

Page 1: ...North America Sales Offices sales spectratime com 41 32 732 16 66 1 512 470 3980 spectratime com An Orolia Group Business Low Cost Low Profile Rubidium Oscillator StarLPRO 1500 High Precision Performance Rubidium Source Telecom Navigation Broadcast Defense Instrument Applications ...

Page 2: ...ONICS PACKAGE 5 2 3 1 PRINCIPAL FUNCTIONS OF THE ELECTRONIC CIRCUITS 5 3 STARLPRO 1500 SPECIFICATIONS 9 4 STARLPRO 1500 INSTALLATION AND OPERATION 9 4 1 INTRODUCTION 9 4 2 SHIPPING AND RECEIVING INFORMATION 9 4 3 MOUNTING 9 4 4 PIN FUNCTION LAYOUT 11 4 5 NORMAL OPERATION 11 4 5 1 ANALOG FREQUENCY ADJUSTMENT 11 4 6 SERIAL INTERFACE OPERATION 11 4 6 1 INTRODUCTION 11 4 6 2 SERIAL INTERFACE CONNECTIO...

Page 3: ...AND BASIC CONFIGURATION The STARLPRO 1500 essentially consists of a voltage controlled crystal oscillator VCXO which is locked to a highly stable atomic transition in the ground state of the Rb87 isotope While the frequency of the VCXO is at the convenient standard frequency of 10 MHz the Rb clock frequency is at 6 834XXX GHz in the microwave range The link between the two frequencies is done thro...

Page 4: ...ximum The absorption cell is filled with metallic vapor which contains Rb85 and Rb87 isotopes and a buffer gas Filtering of the pump light is achieved in the entrance region of the cell by absorption with Rb85 atoms which have an accidental overlap with one of the Rb87 resonance transitions line B integrated filter cell Fig 2 2 Rubidium atomic clock principal block diagram The principal function o...

Page 5: ...s which affect the frequency i e temperature buffer gas light intensity light shift optical Stark effect magnetic field 2nd order Zeeman effect As a consequence the temperatures of lamp and cell the power of the lamp oscillator and the current in the C field coil have to be carefully stabilized 2 3 ELECTRONICS PACKAGE 2 3 1 PRINCIPAL FUNCTIONS OF THE ELECTRONIC CIRCUITS The clock transition of a R...

Page 6: ...y This 5 316 MHz is generated by a synthesizer which is frequency modulated at the rate of fm for dip detection The center frequency of the synthesizer is adjustable with step sizes of 5 12uHz in order to have the capability to adjust the STARLPRO 1500 output frequency 10 MHz with a resolution of 5 12 E 13 per step and also to compensate the frequency shift due to the buffer gas pressure inaccurac...

Page 7: ...iSource StarLPRO 1500 Manual SpectraTime Europe Headquarters North America Sales Offices Page 7 of 12 sales spectratime com 41 32 732 16 66 1 512 470 3980 spectratime com An Orolia Group Business ...

Page 8: ...center frequency adjustment by external potentiometer or external digital to analog converter The correct operation of the unit can be checked by a single open collector type output signal called lock monitor This lock monitor information is generated by the micro controller and is a function of the following parameters Light level intensity Rb signal level detected signal Heaters supply voltages ...

Page 9: ...re must be taken for the transportation of the STARLPRO 1500 to ensure that the maximum acceleration due to a shocks 50g 11ms is not exceeded STARLPRO 1500 contains glass bulbs crystal resonators and crystal filters When STARLPRO 1500 integrated into an instrument such instrument shall be packed in a suitable container similar to containers generally use for the transportation of instruments like ...

Page 10: ...t be given to the operating location of the unit regardless of its application To minimise frequency offsets and or non harmonic distortion the unit should not be installed near equipment generating strong magnetic fields such as generators transformers etc The unit shall not be mounted within high sensitivity radio receiver without special provisions to prevent ratio interferences The general inf...

Page 11: ...of 0 to 5V on Pin 7 Center frequency adjusted at factory is made by leaving this pin open using internal voltage reference of 2 5V 5 This means applying 2 5V on this pin may induce a small frequency offset related to factory setting To avoid such frequency offset it is recommended to measure the voltage on the pin 7 first and then apply the same voltage value on the pin 7 to recover the exact volt...

Page 12: ... CR LF monitors the basic internal signals of the atomic clock The returned answer looks like HH GG FF EE DD CC BB AA CR LF Where each returned byte is an ASCII coded hexadecimal value separated by a Space character All parameters are coded at full scale HH Read back of the user provided frequency adjustment voltage on pin 2 0 to 5V GG reserved FF peak voltage of Rb signal 0 to 5V EE DC Voltage of...

Page 13: ...tion dip level heaters monitoring etc and a comparison with nominal values This principle of operation ensures the user that the STARLPRO 1500 VCXO is still locked correctly onto the Rb atoms resonance 4 7 1 TTL OR CMOS LEVEL LOCK MONITOR GENERATION The lock monitor output can be directly connected to the CMOS load while protected with 1Kohm serial resistor Output impedance 1Kohm Lock 0 5V Logical...

Reviews: