background image

SpectraPure®Inc

 Fax  480.894.6109 Fax us toll-free 1.877.527.7873

E-mail: [email protected] Visit us on the web www.spectrapure.com

7

SpectraPure

®

- INSTALLATION PROCEDURE FOR OPTIONAL FLOATS -

NOTE: Floats are to be 
mounted horizontal when 
dry and float up when 
wet. In most instances we 
recommend locating the 
low float approx. half way 
down your  reservoir. DO 
NOT OVERTIGHTEN when 
installing the floats.

Float Installation:

1.  Instal both the High and Low Floats onto a open container like a
 Rubber 

Maid

TM

 trash can. The floats can be mounted by drilling a

 

5/8” hole. (The High Float shuts down the system, while the Low

 

Float turns the system on).

2.  Connect the floats to the  grey electrical extension cable and then to
 

the 3-socket connector on the S.V.C.

Solenoid Installation:
3.  Un-screw current push-fitting from the carbon tank. (This fitting is
 

the input connection for the tap water).

4.  Thread on the Brass Nipple to the Carbon Tank and then the
 

Solenoid. (Arrow on Solenoid points in the direction where the water

 

flows). PAGE 8.

5.  Connect electrical cable to S.V.C. and thread last two fittings onto the
 

solenoid as shown on page 8.

SVC

SOLENOID

FLOATS

TRANSFORMER

6. 

3/8” BULK HEAD FITTING: Use

 

a paddle bit and carefully drill a.

13/16” hole for installation at the top of the reservoir (above the high 
level float)

7.    Provide over-flow plumbing suitable for your storage tank and installation.

Summary of Contents for The Producer System

Page 1: ...REV 10 31 2012 Reverse Osmosis Water Purification System The Producer System INSTALLATION AND OPERATING MANUAL ...

Page 2: ...tem Specifications 4 System Initialization Tap Water Hook Up 5 Carbon Rinse 5 RO Membrane Rinse 5 Waste Flow Adjustment 5 6 Installation for optional SVC floats 7 8 Maintenance 9 Troubleshooting and Replacement Parts 10 12 TABLE OF CONTENTS Thank You for your purchase of a SpectraPure System With proper installation and maintenance this system will provide you with high quality water for years to ...

Page 3: ...filter is required to remove excess turbidity particulate matter that may cause the membrane to plug NOTE At this point you can add an optional Water Softener to increase the membrane life 3 The third filtration stage of the system is a high rejection thin film composite TFC reverse osmosis membrane It removes over 98 of most inorganic salts all micro organisms and almost all high molecular weight...

Page 4: ...ents For the 1 year TFC membrane pro rated warranty to be honored the following conditions must be met Operating Pressure 40 80 psi 2 75 5 5 bar pH Range 3 11 Maximum Temperature 100 F 38 C Maximum Turbidity 1 0 NTU Maximum Silt Density Index 5 0 based on 15 min test time Maximum Chlorine less than 0 1 ppm Maximum TDS 2000 ppm Maximum Hardness 10 grains 170 ppm as CaCO3 Maximum Iron less than 0 1 ...

Page 5: ...ns of purified water If you have DI resin cartridges after the membrane rinse the membrane with the down stream DI s removed Discard this water down the drain When replacing the membrane bypass the RO water to a drain for 2 gallons Waste to Product Flow Adjustment 6 Place the yellow concentrate tubing and the blue purified water tubing into a drain Do not restrict flow from these lines 7 Open the ...

Page 6: ...ing Connection 3 8T x 1 2MPT DM 10 6 8 12 Brass Swivel Garden Hose Adapter FGH x 1 2FPT GHA 8FPT BR 13 Flow Restrictor 1 4 Needle Valve 14 Tap Water IN Black Tubing 1 2 TUB 8BK 15 Waste Water OUT Yellow Tubing 1 4 TUB 4YW 16 Product Water OUT Blue Tubing 3 8 TUB 6BL 1 Stainless Steel Housing HSG M SS 4x40 2 Carbon Tank w Cap CF2050 0 5CF 3 Clear SlimLine 10 Sediment Housing HSG F 12 10 SL CLR 4 We...

Page 7: ... the system while the Low Float turns the system on 2 Connect the floats to the grey electrical extension cable and then to the 3 socket connector on the S V C Solenoid Installation 3 Un screw current push fitting from the carbon tank This fitting is the input connection for the tap water 4 Thread on the Brass Nipple to the Carbon Tank and then the Solenoid Arrow on Solenoid points in the directio...

Page 8: ...SpectraPure SpectraPure Inc 480 894 5437 Call us toll free 1 800 685 2783 2167 East Fifth St Tempe Arizona 85281 8 ...

Page 9: ...u do get an increase in pressure when running this test then the sediment filter needs to be replaced If the pressure stays the same then you need to back wash the carbon tank An optional manual back wash valve is available for the carbon tank If the carbon tank plugs prematurely and you do not have a manual backwash valve please contact us for further instructions 2 Monitor the Carbon tank for ch...

Page 10: ...gh guidelines for determin ing performance of RO membrane Depending on your tap water chemistry the rejection characteristics of the membrane may vary significantly Method of Calculate Test Results Conclusion Testing Rejection TDS Measure feed water X Is Rejection No Replace Membrane Conductivity RO product water Y greater than Yes Membrane OK Tester for TDS Conductivity 95 Alkalinity Measure feed...

Page 11: ...the unit is used outside avoid putting the system in direct sunlight or connecting it to a garden hose that may be exposed to sunlight Light Sources A Most of the components of this system are plastic and are subject to damage by ultraviolet light from the sun and other sources such as metal halide lighting B Algae is more likely to thrive inside the clear filter housings when exposed to bright li...

Page 12: ...om date of receipt by the buyer providing that the loss of performance was not caused by fouling neglect or water conditions exceeding the feed water parameters listed in the applicable product manual refer to detailed membrane warranty information SpectraPure will on confirmation of loss of performance during the warranty period credit the pro rated amount of the current catalog price of the elem...

Reviews: