8
yellow tubing
capillary tubing
plastic insert
Fig. B: Flow Restrictor Assembly
SEDIMENT PRE-FILTER REPLACEMENT
Maintenance Regime:
For maximum contaminant removal and long
membrane life, the sediment pre-filter must be changed when a 15-20% drop in
pressure is observed OR at least 6-month intervals. If your water contains a great
deal of sediment the pre-filter may require more frequent changes to maintain
adequate production rate and extended membrane life.
Materials Required:
1 micron MicroTec™ Sediment Filter (SF-MT-1-10)
Procedure:
1. Turn off water supply to the system.
2. Using the provided filter wrench, remove the left clear sediment
pre-filter housing. Unscrew it counterclockwise as viewed from the
bottom
3. Remove the old filter from the housing and discard.
4. Thoroughly wash the housing with a mixture of hot soapy water
and a few teaspoons of household bleach. Rinse well with clean
hot
water.
5. Install the new pre-filter onto the round port in the head of the housing,
screw the housing back onto the assembly, and
hand tighten only
.
6. Proceed with carbon block filter replacement.
FILTER REPLACEMENT