SpectraPure MaxPure MPRO-300 RO System Installation And Operating Manual Download Page 15

SpectraPure®Inc

 Fax  480.894.6109 Fax us toll-free 1.877.527.7873

E-mail: [email protected] Visit us on the web www.spectrapure.com

15

SpectraPure

®

ONE YEAR LIMITED WARRANTY

Effective on products purchased after March 10, 2005. 

SpectraPure, Inc.® warrants the product to the original owner only to be free of defects in material and 
workmanship for a period of one year from the date of receipt. SpectraPure’s liability under this warranty 
shall be limited to repairing or replacing at SpectraPure’s option, without charge, F.O.B. SpectraPure’s factory, 
any product of SpectraPure’s manufacture. SpectraPure will not be liable for any cost of removal, installation, 
transportation or any other charges which may arise in connection with a warranty claim. Products which 
are sold but not manufactured by SpectraPure are subject to the warranty provided by the manufacturer 
of said products and not by SpectraPure’s warranty. SpectraPure will not be liable for damage or wear to 
products caused by abnormal operating conditions, accident, abuse, misuse, unauthorized alteration or 
repair or, if the product was not installed in accordance with SpectraPure’s or other manufacture’s printed 
installation and operating conditions, or damage caused by hot water, freezing, flood, fire or acts of God. 

SpectraPure will not be responsible for any consequential damages arising from installation or use of the 
product, including any water or mold damage due to flooding which may occur due to malfunction or faulty 
installation, including, but not limited to failure by installer to over- or under-tighten fittings, housings, and/
or push-style fittings, or improper installation of push-style fittings. Consumable items such as pre filters and 
membranes are not covered under the 1 year warranty.

SpectraPure warrants (pro-rated) the performance of tested SpectraSelect™ RO membrane elements only, for 
one year from date of receipt by the buyer, providing that the loss of performance was not caused by fouling 
, neglect or water conditions exceeding the feed water parameters listed in the applicable product manual 
(refer to detailed membrane warranty information). SpectraPure will, on confirmation of loss of performance 
during the warranty period, credit the pro-rated amount of the current catalog price of the element. The 
disposable filters and  cartridges are not covered under the warranty.

To obtain service under this warranty, the defective system or components must be returned to SpectraPure 
with proof of purchase, installation date, failure date and supporting installation data. Any defective product 
to be returned to the factory must be sent freight prepaid; documentation supporting the warranty claim 
and a Return Goods Authorization (RGA) number must be included. SpectraPure will not be liable for 
shipping damages due to the improper packaging of the returned equipment and all returned goods must 
also have adequate insurance coverage and a tracking number. 

SpectraPure will not pay for loss or damage caused directly or indirectly by the presence, growth, 
proliferation, spread or any activity of “fungus”, wet or dry rot or bacteria. Such loss or damage is excluded 
regardless of any other cause or event that contributes concurrently or in any sequence to the loss. We 
will not pay for loss or damage caused by or resulting from continuous or repeated seepage or leakage 
of water, or the presence or condensation of humidity, moisture or vapor, that occurs over a period of 14 
days or more. “Fungus” and “fungi” mean any type or form of fungus or Mycota or any by-product or type 
of infestation produced by such fungus or Mycota, including but not limited to, mold, mildew, mycotoxins, 
spores, scents or any biogenic aerosols. 

SpectraPure will not be liable for any incidental or consequential damages, losses or expenses arising from 
installation, use, or any other causes. There are no expressed or implied warranties, including merchantability 
or fitness for a particular purpose, which extend beyond those warranties described or referred to above.

* The one year limited warranty does not apply to consumable items, including but not limited 
to, filters and cartridges unless specifically stated above

Summary of Contents for MaxPure MPRO-300 RO System

Page 1: ...REV 02 27 2009 Commercial Grade Reverse Osmosis System Single Membrane Model Produces 300 Gallons Per Day MaxPure MPRO 300 RO System INSTALLATION AND OPERATING MANUAL ...

Page 2: ... prior written permission of SpectraPure Inc System Specifications 3 System Description 4 System Set Up System Initialization 5 Measuring Concentrate to Purified Water Ratio 6 Flow Restrictor Removal Adjustment and Replacement 7 8 System Maintenance Pre Filter Replacement Proceedure 8 9 RO Membrane Replacement Proceedure 10 11 Testing Quality of the Membrane 11 13 Troubleshooting Guide 14 WARRANTY...

Page 3: ...w Rate Concentrate Flow Rate 300 1182 ml min 4728 ml min Reverse Osmosis Membrane Feed Water Requirements Operating Pressure 40 80 psi 2 75 5 5 bar pH Range 3 11 Temperature Range 38 F 100 F 3 C 38 C Maximum Turbidity 1 0 NTU Maximum Silt Density Index 5 0 based on 15 min test time Maximum Chlorine less than 0 1 ppm Maximum TDS 2000 ppm Maximum Hardness 10 grains 170 ppm as CaCO3 Maximum Iron less...

Page 4: ...e used to remove organics and chlorine from the feed water that can damage the membrane The final stage of the system is the R O membrane A high rejection Thin Film Composite TFC membrane is used in this system This removes as much as 98 of most inorganic salts all micro organisms and almost all high molecular weight organics in the water Fig A Single Membrane Filter TFC RO Membrane 1 micron Carbo...

Page 5: ... leaving the system unattended Monitor for at least 72 hrs Note It is recommended that at least 2 gallons 7 57 liters of purified water be discarded now before collecting purified water for use If the unit is not used for several days run the system for at least 10 minutes before collecting any water This will flush out any stale water in the system 4 Finish the installation by connecting the yell...

Page 6: ...te of the concentrate must be a minimum of 3X the product flow rate 3X to 5X is an acceptable concentrate flow rate Procedure 1 Locate the Yellow waste line Direct the waste line into a sink drain 2 Locate the Blue product line Direct the product line into a sink drain 3 Turn on the Feed Supply Valve and let the system run for 20 min 4 Collect product water from the blue line into a measuring cup ...

Page 7: ...ing 3 Using a new single edge razor blade carefully measure and then cut the flow restrictor 4 Re insert the flow restrictor assembly into the yellow tubing and firmly re seat the insert into the end of the yellow tubing by carefully pressing on the insert with your thumbnail Care should be taken not to crush or other wise damage the end of the capillary tubing protruding from the end of the inser...

Page 8: ...to maintain adequate production rate and extended membrane life Materials Required 1 micron MicroTec Sediment Filter SF MT 1 10 Procedure 1 Turn off water supply to the system 2 Using the provided filter wrench remove the left clear sediment pre filter housing Unscrew it counterclockwise as viewed from the bottom 3 Remove the old filter from the housing and discard 4 Thoroughly wash the housing wi...

Page 9: ...eplace the carbon pre filter Materials Required 5 1 micron Carbon Block Filter CF 5 10 CF 1 10 Procedure 1 Turn off water supply to the system 2 Using the provided filter wrench remove the right clear carbon block filter housing Unscrew it counterclockwise as viewed from the bottom 3 Remove the old filter from the housing and discard 4 Thoroughly wash the housing with a mixture of hot soapy water ...

Page 10: ...e into the housing with the double O ring end first Fig E The tube must fit into the recess at the bottom of the membrane housing When the membrane is aligned with the hole firmly push the membrane into the hole until it bottoms out 8 Place the black housing O ring on the housing rim and carefully screw the lid back on to the base 9 Reconnect the black tubing to the membrane feed push fitting 10 D...

Page 11: ...mbrane Element black membrane brine seal black membrane housing O ring membrane product water tube double O ring end of membrane product water stem tube TESTING QUALITY OF THE MEMBRANE Membrane Output Calculation Membranes produce the rated gallons per day GPD at 60 psi 4 1 bars operating pressure 77 F 25 C operating temperature and 500 ppm total dissolved solids Membrane output gallons per day GP...

Page 12: ...3 6 12 0 661 71 6 22 0 912 89 6 32 1 232 55 4 13 0 684 73 4 23 0 941 91 4 33 1 267 57 2 14 0 707 75 2 24 0 970 93 2 34 1 304 Membrane Output Calculation Example What is the expected GPD from a 75 GPD System at 40 psi pressure and 60 F water temperature PCF 40 60 0 666 TCF 0 754 from Table 1 Expected GPD 75 0 666 0 754 37 7 GPD 15 Performance Test The performance of a RO membrane is measured in ter...

Page 13: ...onductivity in the above procedure could be replaced by hardness alkalinity nitrate phosphate silica etc measured in ppm or mg l Rejection of the RO Membrane Calculation Example 1 Tap water hardness 150 ppm X 2 RO water hardness 7 ppm Y 3 X Y 143 ppm 4 X Y X 143 150 0 953 5 Rejection X Y X 100 0 953 100 95 3 Membrane Hardness Rejection 95 3 Membrane OK ...

Page 14: ...pending on your tap water chemistry the rejection characteristics of the membrane may vary significantly Method of Calculate Test Results Conclusion Testing Rejection TDS Measure feed water and Is Rejection No Replace Membrane Conductivity RO product water TDS greater than Yes Membrane OK Tester Conductivity 95 Alkalinity Measure feed water and Is Rejection No Replace Membrane Test Kit RO product ...

Page 15: ...glect or water conditions exceeding the feed water parameters listed in the applicable product manual refer to detailed membrane warranty information SpectraPure will on confirmation of loss of performance during the warranty period credit the pro rated amount of the current catalog price of the element The disposable filters and cartridges are not covered under the warranty To obtain service unde...

Page 16: ...Replacement Part SF MT 1 10 1 micron MicroTec Sediment Filter CF 5 10 5 micron Carbon Block Pre Filter CF 1 10 1 micron Carbon Block Pre Filter MEM 0300 300 gpd TFC Membrane FR 300 Flow Restrictor for 300 gpd System GHA 6 JG Gard Hose Adapter with 3 8in Tubing Push Fitting WR UNIV Universal Filter Wrench REPLACEMENT PARTS ...