NON-AIR GAP FAUCET INSTALLATION
(MPDW-90)
A. Place the chrome counter plate and large rubber washer over the threaded shaft on the faucet and place in
hole previously drilled on page 4.
B. Place the small rubber washer, locating washer, flat metal washer, and hex nut in sequence over the threaded
shaft and temporarily hand-tighten.
C. Insert the Blue Tube into the Compression Nut with the threads towards the end of the tube. Then add the
Compression Sleeve.
D. Place the Insert into the end of the Blue Tubing. Make sure you push the insert in all the way. Screw the
Compression Nut onto the threaded shaft.
E. Securely tighten both hex nut and Compression Nut.
F. DO NOT CUT EXCESS TUBING AT THIS POINT. YOU WILL NEED THE TUBING TO INSTALL TANK.
TIP:
When connecting the tubes to the hose barbs, try using HOT water to soften the plastic tubes. When connecting
the drain lines to the saddle, make the lengths as short and straight as possible to reduce drainage noise.