TERMINAL BLOCK
1
2
3
4
5
6
+DATA
-DATA
GROUND
RS-422/485 INTERFACE
TIMEVIEW 400
FIGURE 2-10 COMPUTER CONNECTION
FIGURE 2-10 COMPUTER CONNECTION
FIGURE 2-10 COMPUTER CONNECTION
FIGURE 2-10 COMPUTER CONNECTION
FIGURE 2-10 COMPUTER CONNECTION
Multiple TimeView 400 clocks can be synchronized by a
single computer when connected as shown in Figure 2-11.
Each clock must have DIP switch 7 ON to enable computer
set operation. Terminate the last clock in the line by
placing DIP switch 10 in the ON position.
TIMEVIEW
400
TIMEVIEW
400
TIMEVIEW
400
RS-485 DATA BUS
RS-485
INPUT/OUTPUT
TERMINATE
END DEVICE
FIGURE 2-11 MULTIPLE CLOCK CONNECTION
FIGURE 2-11 MULTIPLE CLOCK CONNECTION
FIGURE 2-11 MULTIPLE CLOCK CONNECTION
FIGURE 2-11 MULTIPLE CLOCK CONNECTION
FIGURE 2-11 MULTIPLE CLOCK CONNECTION
The computer can synchronize up to 32 clocks over a total
cable length of 4000 feet.
Page 2-17