background image

O

O

N

N

S

S

I

I

P

P

 

 

O

O

2

2

D

D

4

4

 

 

O

O

w

w

n

n

e

e

r

r

s

s

 

 

M

M

a

a

n

n

u

u

a

a

l

l

 

 

 

 
 
 
 

Rev.1.3  (June,2013) 

 

 

 

 

 

 

Note 

 

This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  A  digital  device, 

pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection 

against  harmful  interference  in  a  residential  installation.  This  equipment  generates,  uses  and  can 

radiate radio frequency energy and, if not installed and used in accordance with the instructions, may 

cause harmful interference to radio communications. However, there is no guarantee that interference 

will not occur in a particular installation. If this equipment does cause  harmful interference to radio or 

television  reception,  which  can  be  determined  by  turning  the  equipment  off  and  on,  the  user  is 

encouraged to try to correct the interference by one or more of the following measures:   

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into and outlet on a circuit different from that to which the receiver is 

connected 

 

Consult the dealer or an experienced radio/TV technician for help. 

 

Directions 

Be careful not to cause any physical damage by dropping or throwing ONSIP O2D4. Especially keep the 

device out of reach from children. 

Do not disassemble ONSIP O2D4. No after service is assumed when disassembled. 

 

Use only the power adapter provided with ONSIP O2D4. 

Be careful to prevent moisture or water penetration into the unit. Particular attention is needed when 

installing ONSIP O2D4. The screw holes for the installation screws and pipe should be maintained water 

tight during the whole life time of the product. 

All the electrical connection wires running into the unit should be prepared so that water from the outside 

cannot flow into the unit through the surface of the wires. Penetration of the moisture through the wire for 

extended period can cause malfunction of the unit or deteriorated image. 

 

Summary of Contents for ONSIP O2D4

Page 1: ...O ON NS SI IP P O O2 2D D4 4 O Ow wn ne er r s s M Ma an nu ua al l Rev 1 3 June 2013 1 ONSIP O2D4...

Page 2: ...or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into and outlet on a circuit different from that to which the receiver is connected C...

Page 3: ...3 th 2013 1 0 First manual revision creation May 24 th 2013 1 1 Text revisions June 19 th 2013 1 3 Updated package contents drawings Caution Any changes or modifications in construction of this device...

Page 4: ...plications of ONSIP O2D4 8 2 Product Description 9 2 1 Contents 9 2 2 Product Preview 9 2 3 Physical description 10 2 4 Functional Description 12 3 Getting Started 15 4 1 PC Requirement 15 4 2 Quick I...

Page 5: ...solutions running on PC PDA or mobile phones Real time 2 way communication is available through bidirectional audio communication feature Designed to be a stand alone streaming audio video transmissio...

Page 6: ...Sensor In 1 NC NO Selectable Relay Output 1 For alarm annunciation or remote ON OFF control 30V 1A Mic Line In Selectable in Admin page Line Out 1 V p p output for amplified speaker Power Supply PoE P...

Page 7: ...an nu ua al l Rev 1 3 June 2013 7 IP filtering for restricting administrative access for audio and bi audio Time management Sync to PC Synchronize to PC Manual Manual time setting Internet Time Server...

Page 8: ...O2D4 Security surveillance buildings stores manufacturing facilities parking lots banks government facilities military etc Remote monitoring hospitals kindergartens traffic public areas etc Teleconfe...

Page 9: ...it Tools and Mounting Screws Screws M4x16L 4EA 4x16L 4EA L wrench CD Software User s Guide Quick Reference Guide Quick installation guide 2 2 Product Preview ONSIP O2D4 IP Installer VMS Software Speco...

Page 10: ...NS SI IP P O O2 2D D4 4 O Ow wn ne er r s s M Ma an nu ua al l Rev 1 3 June 2013 10 2 3 Physical description 2 3 1 External View Figure 2 1 External view of ONSIP O2D4 Figure 2 2 Connection Cable of...

Page 11: ...P O O2 2D D4 4 O Ow wn ne er r s s M Ma an nu ua al l Rev 1 3 June 2013 11 Figure 2 3 Adjustment knobs for the Camera Figure 2 4 3 axis based camera position control Manual adjustment of Pan Tilt and...

Page 12: ...Color Red Green It will be lit in green or red depending on the status Green Green color indicates that the camera is in normal operation mode Continuous green indicates that data transmission is poss...

Page 13: ...which needs power switching beyond this limit use additional relay switch as shown in the right of Figure 2 8 Figure 2 3 RELAY Output connection left switching requirement below 30V 2A right switching...

Page 14: ...Open CollectorType Photo Coupler Figure 2 4 SENSOR input and connection of the sensor Factory Default Switch A switch provided for returning the IP camera to factory default state Open the dome cover...

Page 15: ...in a PC running client programs Minimum requirement of the PC is described below Minimum Requirement Recommended Specification CPU Intel Core i3 3Ghz Intel Core i7 Main Memory 2GB 4GB Operating System...

Page 16: ...deo connection PC is needed to assign IP address to ONSIP O2D4 2 In the case of using PoE connect the PC and ONSIP O2D4 to the network using one of the following ways If your LAN Switch does not suppo...

Page 17: ...nection information to Speco NVR program before connection Insert the CD provided with product into the PC and install Speco NVR Figure 4 2 Speco NVR Follow the sequence below for setting the IP param...

Page 18: ...best suits from the drop down list in 5 You can choose either Static or ADSL and Auto DHCP respectively If ADSL and Auto are selected the fields in 6 are deactivated In case of ADSL fill the User Nam...

Page 19: ...module should be installed on your PC before actual connection If your PC is not connected to the internet you cannot download Active X module Most convenient way of installing the Active X module is...

Page 20: ...ID Password and port and then click the save button After assignment procedure you must click the SAVE button You can see the live video when you click the live view button as below When you exit Spec...

Page 21: ...isticated target application parameters need to be changed through the admin page The admin page can be connected through http IP_address HTTP_port_number admin htm ID and password of the administrato...

Page 22: ...the product 2 The LAN switch supports standard PoE Make sure that both the IP camera and the LAN switch support standard PoE IEEE 802 3af In case of DC adapter If PoE is not applied the power and netw...

Page 23: ...rt Run Cmd Ping IP address Ex Ping 172 16 42 51 If Reply from message is returned in the figure below the network connection is in normal state Try connection to the video again If the problem persist...

Page 24: ...proper recording and still video capture in Speco NVR and Web Viewer Windows Vista 1 UAC User Access Control configuration 1 Double click User Accounts in control panel 2 Double click Turn User Accoun...

Page 25: ...O Ow wn ne er r s s M Ma an nu ua al l Rev 1 3 June 2013 25 Windows 7 1 UAC User Access Control configuration 1 Double click User Accounts in control panel 2 Double click Change User Account Control s...

Page 26: ...2D D4 4 O Ow wn ne er r s s M Ma an nu ua al l Rev 1 3 June 2013 26 2 Privilege Level Control 1 Select NVR icon on the desktop 2 Click right mouse button and select properties 3 Check Privilege Level...

Page 27: ...June 2013 27 5 4 Technical Assistance If you need any technical assistance please contact your dealer For immediate service please provide the following information 1 Model name 2 MAC address and Regi...

Reviews: