background image

6

Important Safety Instructions

When installing and using this electrical equipment, basic safety precautions should always be 

followed, including the following:

READ AND FOLLOW ALL INSTRUCTIONS

WARNING:

 To reduce the risk of injury, do not permit children to use this product unless they are closely 

supervised at all times.

WARNING:

 Risk of Electrical Shock. Connect only to a grounding type receptacle protected by a ground-

fault circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify that the receptacle is 

protected by a GFCI.

The unit must be connected only to a supply circuit that is protected by a ground-fault circuit-interrupter 

(GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test 

the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be 

restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to 

the pump without the test button being pushed, a ground current is flowing, indicating the possibility of an 

electric shock. Do not use this pump. Disconnect the pump and have the problem corrected by a qualified 

service representative before using.

CAUTION:

 This pump is for use with permanently installed pools and may also be used with hot tubs 

and spas if so marked. Do not use with storable pools. A permanently installed pool is constructed in or 

on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is 

constructed so that it may be readily disassembled for storage and reassembled to its original integrity.

TO REDUCE THE RISK OF ELECTRICAL SHOCK, 

connect ground wires to grounding screw located in 

the motor. Use no smaller than a #12 AWG (3.3mm2) wire.

TO REDUCE THE RISK OF ELECTRICAL SHOCK, 

a bonding connector is provided for bonding to 

metal water pipes, metal rails, or other metal within 5 feet of the swimming pool. All local points should be 

bonded with a #8 AWG (8.4mm2) wire.

SAVE THESE INSTRUCTIONS.

Badu EcoM3 - Variable Speed

The Badu EcoM3 - Variable Speed swimming pool pump is both environment friendly and cost efficient. 

This revolutionary three speed pump provides the pool owner a simple three button control to operate 

the pump, greatly reducing the operating cost at a reasonable investment. The robust pump is based on 

Speck Pumps energy efficient design platform. The Badu EcoM3 - Variable Speed high performance, 

medium head pump uses a state of the art axial flux permanent magnet brushless-DC motor controlled 

by advance logic electronics. Providing cooler and quieter operation at a fraction of the cost of a standard 

PSC motor. 

General Description

Summary of Contents for Badu EcoM3V

Page 1: ...Installation Operating and Service Manual Badu EcoM3V Variable Speed Pool Pump...

Page 2: ...ll Free 800 223 8538 Phone 904 739 2626 Fax 904 737 5261 Website www usa speck pumps com Manufactured by Speck Pumps Jacksonville Florida USA 2012 All Rights Reserved This document is subject to chang...

Page 3: ...Operation 12 Start Up Guide 12 Changing the Default Speed 13 Adjusting the Speed 14 5 Service and Maintenance 15 Routine Maintenance 15 Winterizing 16 6 Troubleshooting 16 Controller Malfunction Warn...

Page 4: ...ion outlet cover is missing broken or loose The following guidelines provide information for pump installation that minimizes risk of injury to users of pools spas and hot tubs Entrapment Protection T...

Page 5: ...ished edition of ANSI ASME A112 19 8 ANSI APSP 16 2011 the standard for Suction Fittings For Use in Swimming and Wading Pools Spas Hot Tubs and Whirlpool Bathtub Applications Testing and Certification...

Page 6: ...use with permanently installed pools and may also be used with hot tubs and spas if so marked Do not use with storable pools A permanently installed pool is constructed in or on the ground or in a bu...

Page 7: ...ed control panel provides manual speed controls for the pump There are three preset speed buttons that can be selected LOW MEDIUM and HIGH Controls and LEDs 1 LOW MED and HIGH buttons LED Press one of...

Page 8: ...the vicinity of this pump DO NOT store pool chemicals near the pump 6 DO NOT remove any safety alert labels such as DANGER WARNING or CAUTION Keep safety labels in good condition and replace any missi...

Page 9: ...hould always be followed The wiring of the motor should be done by a licensed electrician in accordance with local codes BONDING AND GROUNDING 1 The motor frame must be grounded to a reliable groundin...

Page 10: ...onto the motor Carefully lift the top panel and turn it over to expose the inside terminal box See Figure 2 2 The terminal box is supplied with a 1 2 14 NPS threaded hole Use only liquid tight fitting...

Page 11: ...system during the filling process This air will compress when the system is pressurized Should the system fail this trapped air can propel debris at a high speed and cause injury Every effort to remov...

Page 12: ...lid and fill the basket with water before starting the pump 3 Prior to replacing the lid check for debris around the lid o ring seat Debris around the lid o ring seat will make it difficult to prime...

Page 13: ...ng power to the unit Please follow all local state regulations regarding pool motor and timer speeds settings when choosing the default speed 1 Allow the pump to achieve prime if starting the system f...

Page 14: ...ess the STOP button or wait 30 seconds without pressing any buttons NOTE If the power is shut off or the pump is stopped using the stop button upon powering up the pump will run a two 2 minute prime o...

Page 15: ...o 10 seconds All LED light will be fully lit The LED s will blink to indicate the factory defaults were re established Adjusting the Speeds continued Routine Maintenance This pump requires little or n...

Page 16: ...xpected Allowing the pump to freeze will cause severe damage and void the warranty There are two options when winterizing the pump Option 1 1 Drain all the water from the pump system equipment and pip...

Page 17: ...rs during start up A Low Voltage During the initial start up 6 12 seconds delay there is a momentary power drop in which case the pump will restart itself after the voltage is above 208V for a period...

Page 18: ...r shaft noting the way it was originally installed CAUTION Do not damage the ceramic or carbon surfaces of the seal If the surfaces is damaged leaks will occur Figure 3 Removal and Replacement of the...

Page 19: ...essing together 16 Make sure the diffuser and casing o rings are in place and free of debris Slide the motor flange into the casing 17 Tighten the eight screws using a cross pattern from side to side...

Page 20: ...DRAIN 3 8 WITH GASKET CASING 2920889410 894 1 2 LEGO SPACER 2920889420 595 1 GASKET 1 4 x 7 16 x 1 2991000088 914 1 8 SCREW CASING HEX SLOT M7 x 48mm SS 2920141210 412 5 1 O RING DIFFUSER 90 x 5mm 29...

Page 21: ...cturer supplies a limited warranty to the original consumer purchaser of the pump and motor on the following terms and conditions 1 The pump and motor are warranted to be free from defects in material...

Page 22: ...2999999995 Rev 05 2012...