Plumbing Installation - continued

If the pump is located below water level, isolation valves must be installed on both sides of the pump to 

prevent the back flow of pool water during any routine or required servicing. The Badu EcoM3 - Variable 

Speed comes  equipped with unions on both the suction and discharge ports. This feature simplifies 

installation and service and eliminates the possibility of leaks at the threaded adaptors. 

Before starting the pump for the first time, remove the see-through lid. (Turn lid counter clockwise to 

remove.) Fill strainer tank with water until it is level with the suction inlet. Replace lid, making sure the 

o-ring is not damaged. Screw down, hand tight.

Suction and discharge line should be independently supported at a point near the pump to avoid strains 

being placed on the pump. Always use properly sized valves.

Use the fewest fittings as possible. Each additional fitting has the effect of moving the equipment farther 

away from the water. 

NOTE: If more than ten (10) suction fittings are needed, the pipe size must be increased.

Every new installation must be pressure tested according to local codes. 

See the Pressure Testing 

Section on page 7

 

Bonding and Grounding 

When installing and using the motor, basic safety precautions should always be followed. The wiring of 

the motor should be done by a licensed electrician in accordance with local codes. 

BONDING AND GROUNDING

1. The motor frame must be grounded to a reliable grounding point using a solid copper conductor, 

No. 8 AWG or larger. In Canada, No. 6 AWG or larger must be used. If the pump is installed within five 

(5) feet of the inside walls of the swimming pool, spa, or hot tub, the motor frame must be bonded to 

all metal parts of the swimming pool, spa, or hot tub structure and to all electrical equipment, metal 

conduit, and metal piping within five (5) feet of the inside walls of the swimming pool, spa, or hot tub.

2. Bond the motor using the provided external lug.

 

WARNING: Always disconnect the power source before working on a motor or its connected 

load.

WARNING: In order to avoid the risk of property damage, severe personal injury, and/or death, 

make sure that the control switch, time clock, or control system is installed in an accessible 

location, so that in  the event of an equipment failure or loose plumbing fitting, the equipment 

can be easily turned off.

CAUTION: The pump must be permanently connected to a dedicated electrical circuit. No 

other equipment, lights, appliances, or outlets may be connected to the pump circuit, with the 

exception of devices that may be required to operate simultaneously with the pump, such as a 

chlorinating device or heater.

WARNING: Motor is fitted with internal auto reset. May restart without warning!

Summary of Contents for Badu EcoM3V

Page 1: ...Installation Operating and Service Manual Badu EcoM3V Variable Speed Pool Pump...

Page 2: ...ll Free 800 223 8538 Phone 904 739 2626 Fax 904 737 5261 Website www usa speck pumps com Manufactured by Speck Pumps Jacksonville Florida USA 2012 All Rights Reserved This document is subject to chang...

Page 3: ...Operation 12 Start Up Guide 12 Changing the Default Speed 13 Adjusting the Speed 14 5 Service and Maintenance 15 Routine Maintenance 15 Winterizing 16 6 Troubleshooting 16 Controller Malfunction Warn...

Page 4: ...ion outlet cover is missing broken or loose The following guidelines provide information for pump installation that minimizes risk of injury to users of pools spas and hot tubs Entrapment Protection T...

Page 5: ...ished edition of ANSI ASME A112 19 8 ANSI APSP 16 2011 the standard for Suction Fittings For Use in Swimming and Wading Pools Spas Hot Tubs and Whirlpool Bathtub Applications Testing and Certification...

Page 6: ...use with permanently installed pools and may also be used with hot tubs and spas if so marked Do not use with storable pools A permanently installed pool is constructed in or on the ground or in a bu...

Page 7: ...ed control panel provides manual speed controls for the pump There are three preset speed buttons that can be selected LOW MEDIUM and HIGH Controls and LEDs 1 LOW MED and HIGH buttons LED Press one of...

Page 8: ...the vicinity of this pump DO NOT store pool chemicals near the pump 6 DO NOT remove any safety alert labels such as DANGER WARNING or CAUTION Keep safety labels in good condition and replace any missi...

Page 9: ...hould always be followed The wiring of the motor should be done by a licensed electrician in accordance with local codes BONDING AND GROUNDING 1 The motor frame must be grounded to a reliable groundin...

Page 10: ...onto the motor Carefully lift the top panel and turn it over to expose the inside terminal box See Figure 2 2 The terminal box is supplied with a 1 2 14 NPS threaded hole Use only liquid tight fitting...

Page 11: ...system during the filling process This air will compress when the system is pressurized Should the system fail this trapped air can propel debris at a high speed and cause injury Every effort to remov...

Page 12: ...lid and fill the basket with water before starting the pump 3 Prior to replacing the lid check for debris around the lid o ring seat Debris around the lid o ring seat will make it difficult to prime...

Page 13: ...ng power to the unit Please follow all local state regulations regarding pool motor and timer speeds settings when choosing the default speed 1 Allow the pump to achieve prime if starting the system f...

Page 14: ...ess the STOP button or wait 30 seconds without pressing any buttons NOTE If the power is shut off or the pump is stopped using the stop button upon powering up the pump will run a two 2 minute prime o...

Page 15: ...o 10 seconds All LED light will be fully lit The LED s will blink to indicate the factory defaults were re established Adjusting the Speeds continued Routine Maintenance This pump requires little or n...

Page 16: ...xpected Allowing the pump to freeze will cause severe damage and void the warranty There are two options when winterizing the pump Option 1 1 Drain all the water from the pump system equipment and pip...

Page 17: ...rs during start up A Low Voltage During the initial start up 6 12 seconds delay there is a momentary power drop in which case the pump will restart itself after the voltage is above 208V for a period...

Page 18: ...r shaft noting the way it was originally installed CAUTION Do not damage the ceramic or carbon surfaces of the seal If the surfaces is damaged leaks will occur Figure 3 Removal and Replacement of the...

Page 19: ...essing together 16 Make sure the diffuser and casing o rings are in place and free of debris Slide the motor flange into the casing 17 Tighten the eight screws using a cross pattern from side to side...

Page 20: ...DRAIN 3 8 WITH GASKET CASING 2920889410 894 1 2 LEGO SPACER 2920889420 595 1 GASKET 1 4 x 7 16 x 1 2991000088 914 1 8 SCREW CASING HEX SLOT M7 x 48mm SS 2920141210 412 5 1 O RING DIFFUSER 90 x 5mm 29...

Page 21: ...cturer supplies a limited warranty to the original consumer purchaser of the pump and motor on the following terms and conditions 1 The pump and motor are warranted to be free from defects in material...

Page 22: ...2999999995 Rev 05 2012...

Reviews: