![Speck pumpen BADU BNR 400 Operation Manual Download Page 47](http://html.mh-extra.com/html/speck-pumpen/badu-bnr-400/badu-bnr-400_operation-manual_1341776047.webp)
Description
01|2020 EN
13
3.2 Control
Operating mode
Under operating mode, the various
operating modes can be selected
manually.
• Level
control
• Manual
Feeding
Level control is the default setting. This is
shown with a tick in the selection menu.
Settings Level control
The delay times, the water metering and
the fill-up time can be set in the Settings
Level control menu. A delay time between
2 seconds and 1 hour can be selected. The
quantity of water consumed per minute can
be be set under Water metering. This value
can be read on the water meter. The fill-up
time can be set under Time.
Settings Protection
The safety time, the limit and an anti-
blocking protection can be set in the
Settings Protection menu.
The Fill-up safety time prevents the pool
from overflowing in the case of a sensor
error or permanent filling in case of too
great leakage. The power to Lp/Np is
switched off at the end of the safety time.
The maximum number of fillings is
controlled by Limit fill-up.
To prevent the solenoid valve from
blocking during long refilling periods,
voltage is applied to Lp/Np (or 11_14) to
switch the valve.
Summary of Contents for BADU BNR 400
Page 3: ...DE DE DE Originalbetriebsanleitung BADU BNR 400 ...
Page 34: ......
Page 35: ...EN EN EN Translation of original operation manual BADU BNR 400 ...
Page 66: ......
Page 67: ...FR FR FR Traduction des instructions d utilisation originale BADU BNR 400 ...
Page 100: ......
Page 101: ...NL NL NL Vertaling van de oorspronkelijke gebruikershandleiding BADU BNR 400 ...
Page 132: ......
Page 133: ...IT IT IT Traduzione del manuale d istruzioni originali BADU BNR 400 ...
Page 164: ......
Page 165: ...ES ES ES Traducción de las instrucciones originales para el manejo BADU BNR 400 ...
Page 197: ......
Page 198: ......