USING RS232
Settings
The serial baud rate for this protocol is 9,600bps. All serial communications use 8 data bits, no parity and one stop bit (8-N-1).
Serial hardware flow control (i.e., RTS/CTS and DTR/DSR) and software flow control (i.e., XON/XOFF) protocols are not used
and will be ignored.
Programming Commands
All command packets shall be of the following format:
*<command><parameter 1><parameter 2><CR>
Notes: Each <…> represents a single ASCII character. <CR> represents a carriage return.
The Controller will ACK each recognized command with an asterisk (*). The Controller will NACK each unrecognized com-
mand with a period (.).
TIME Series Controller
Page 6
Command
Equivalent Remote Button
Action
*Z01<CR>
Zone 1 Selects Zone 1 speakers
*Z02<CR> Zone 2 Selects Zone 2 speakers
*Z03<CR> Zone 3 Selects Zone 3 speakers
*Z04<CR> Zone 4 Selects Zone 4 speakers
Zone Command:
*Z<parameter 1><parameter 2><CR>
Command
Equivalent Remote Button/Action
Action
*P00<CR>
None Off Command
*P01<CR>
None On Command
*P02<CR>
On/Off On/Off Command
Power Command:
*P<parameter 1><parameter 2><CR>
Command
Equivalent Remote Button/Action
Action
*S++<CR>
Speaker
Scrolls Selected Speaker Forward 1
*S--<CR>
Speaker Select - Scrolls Selected Speaker Back 1
*S01<CR>
None Speaker 1 Select
*S02<CR>
None Speaker 2 Select
*S03<CR>
None Speaker 3 Select
*S04<CR>
None Speaker 4 Select
*S05<CR>
None Speaker 5 Select
*S06<CR>
None Speaker 6 Select
*S07<CR>
None Speaker 7 Select
*S08<CR>
None Speaker 8 Select
*S!!<CR>
None
Cancels select mode
Speaker Select Command:
*S<parameter 1><parameter 2><CR>
Command
Equivalent Remote Button/Action
Action
*R++<CR>
Rotate Dial Clockwise Rotates Speaker Right
*R--<CR>
Rotate Dial Counter-Clockwise Rotates Speaker Left
Rotate Speaker Command:
*R<parameter 1><parameter 2><CR>
*R!!<CR>
None Stop