MZC-64 SYSTEM INSTALLATION AND CONNECTIONS

INSTALLATION-HEAD END

The MZC-64 and external source components will typically be installed at the System Head-End. They can be mounted on shelves 
in a wall unit, entertainment center or closet, or rack mounted in a standard 19” rack mount system. Source components such as 
DVD/CD players and VCR’s should be installed so the user has easy access for loading discs and tapes. 

Though heavy, the MZC-64 should be mounted at the top of the equipment rack so heat generated by the controller will not af-
fect the other system components. Always leave adequate space between system and source components for airflow. Failure to 
do so can cause damage to the components from overheating. Never block the vent holes on the top or bottom of the MZC-64. 
Blocking the vent holes will cause the controller to overheat. For additional information on MZC-64 systems using multiple controllers 
or external amplifiers, see: 

MZC-64 Hardware Installation Instructions

.

CONNECTIONS-HEAD END

Keypads

1.  Connect each keypad run to the appropriate Zone on the MZC-64. Be sure CAT-5 cable and RJ45 connectors are properly 

configured per the MZC-64 Quick Start Guide 

Keypad Connections Table

NOTE:

 

IMKP

 uses the same pin-out as EZ-Pad. 

MODE 

3.1

 uses CAT-5 terminated with RJ45 connectors in a pin to pin (pass-through) configuration.

External Source Components

1.  Connect the L & R line-level audio OUT of each external source component to the appropriate L & R line-level audio SOURCE 

IN on the MZC-64 Rear Panel. Use quality Audio RCA-RCA stereo cables terminated with gold connectors.

Emitters (Source)

1.  Carefully attach a SpeakerCraft IR Emitter (Models: IRE-0.5, 1.0, 2.0, 3.0, 4.0) over the IR eye on the front panel of each external 

source component to be controlled via infrared. 

2.  Carefully pull the emitter wire to the rear panel of the MZC-64. Do not block accesses for discs and tapes. Do not pinch emitter 

wires between components.

3.  Connect the 3.5mm mini plug to the appropriate Source IR OUT.

Speakers

1.  Connect each Zone speaker run to the appropriate Zone SPEAKER terminal using the included removable screw down con-

nectors.

2.  Strip approximately 

1

4

 inch of each lead and twist the stripped ends so there are no loose strands that can cause shorts.

3.  Carefully slide the individual conductors into the appropriate L+,L-/R-,R+ speaker terminals on the removable screw down con-

nector.

4.  Visually check for loose ends. Lightly pull the wire to confirm connection.
5.  Plug connector into the appropriate Zone SPEAKER Terminal.

INSTALLATION-ZONES

Keypads should typically be located near a door or entry point to a room. Avoid mounting keypads, IR receivers, volume controls 
or any other control devices in areas of high moisture such as sinks, showers, bathtubs etc. Care should be taken to avoid mount-
ing Keypads and IR receivers in locations subject to direct sunlight. Sunlight can interfere with system operation and, in time, cause 
deterioration to the keypad and trim plate materials.

WARNING: Never mount a keypad, IR receiver or volume control in the same J-box as high voltage devices. This can affect 
system performance and is a violation of Electrical Code in some areas. (Be aware of local Electrical and Building Codes. 
These codes can affect the type of J-boxes permitted, mandate wire specifications and regulate other aspects of the installa-
tion that may not pass inspection if necessary.)

CONNECTIONS-ZONES

Keypads

1.  Connect each Keypad cable run to the appropriate Zone Keypad. When not using RJ45 connectors, be sure to maintain 

consistent color code when making connections . When using RJ45 connectors, be sure the RJA-1.1 adaptor pins are oriented 

properly (EZ-Pad). Refer to the MZC-64 Quick Start Guide 

Keypad Connection Table

.

2.  Install each Keypad into a proper low-voltage J-box and finish with an appropriate trim plate (Not included with EZ-Pad).

Speakers

1.  Connect ZONE SPEAKERS L+,L-/R-,R+ OUTPUTS from the MZC-64, to the appropriate Zone Speaker pair.

2.  Strip approximately 1⁄4 inch of each lead and twist the stripped ends so there are no loose strands that can cause shorts.

3.  Connect as appropriate to the L+,L-/R-,R+ terminals on each speaker.

4.  Visually check for loose ends. Lightly pull the wire to confirm connection.

5.  Install speakers into dry-wall cut-outs or SpeakerCraft InstaLLock™ New Construction Brackets (if used) as appropriate.

7

Summary of Contents for MZC-64

Page 1: ...ms with multiple controllers external amplifiers multi room zones or when changing the layout of the keypad buttons it is highly recommended that the MZC 64 Hardware In stallation Instructions be used...

Page 2: ...EYPAD SPKRS L R ZONE 3 SOURCE 4 OUT IR LOOP L R INPUTS LOOP L R PRE OUT VC NVC IR OUT KEYPAD SPKRS L R ZONE 4 SOURCE 5 OUT IR LOOP L R INPUTS LOOP SOURCE 6 OUT IR LOOP L R INPUTS LOOP CONTACT CLOSURE...

Page 3: ...Configured for T568B Standard pin out Allows runs of up to 1000 13 L R SPEAKERS Four removable screw down connectors one terminal per zone provide quick connection of the internal amplifiers to Zone s...

Page 4: ...is on 2 KEYPAD EXPANSION Terminal This 16 pin header terminal is used to inter connect the EZ Pad modules for expansion as needed A ribbon cable is packed with each NKP 1 0 and FKP 1 0 for making the...

Page 5: ...ins into the keypad s EZ Connect Terminals and snap the levers in place Be sure RJA 1 1 pin orientation is correct prior to powering up the system CAT 5 cable should be configured in a pass through pi...

Page 6: ...YPAD SPKRS L R ZONE 4 SOURCE 5 OUT IR LOOP L R INPUTS LOOP SOURCE 6 OUT IR LOOP L R INPUTS LOOP CONTACT CLOSURE EXPANSION PORTS RS232 DATA I O PHONE PAGE IN DOORBELL STATUS IN 1 2 CONTROL PORT FIRMWAR...

Page 7: ...terminal using the included removable screw down con nectors 2 Strip approximately 1 4 inch of each lead and twist the stripped ends so there are no loose strands that can cause shorts 3 Carefully sl...

Page 8: ...Crosstalk Between Sources 65 dB 10 kHz S N Ratio Re Rated output 100 dB IEC A source inputs shorted Bass Control Range 10 dB 100 Hz Treble Control Range 10 dB 10 kHz CONTROL SECTIONS Contact Closures...

Reviews: