3.  RS232 DATA I/O – 

One, DB9F terminal allows the MZC-64 to control certain RS232 compatible devices such as source 

 

components and lighting systems.

4.  PHONE PAGE IN – 

One, RCA jack provides input for line level audio source such as telephone systems, door mics or other 

 

audio paging sources. This jack is programmable in EZ-Tools, to turn on as an event, when triggered by the DOORBELL/STATUS 

 

IN Jacks, item 5.

5.  DOORBELL/STATUS IN 1 & 2 – 

Two, 3.5mm mini jack trigger inputs work in conjunction with the PHONE PAGE IN jack, item 4.  

 

When triggered, the Phone input can be turned on in selected zones as programmed in 

EZ-Tools

. If Audio paging is not 

 

required, these  jacks can also be programmed as STATUS INPUTS for power management of Source or Zone components. 

 

POLARITY: 

TIP= +V; SLEEVE=GND. 

INPUT VOLTAGE:

 3-30V AC or DC to trigger the ON condition. Voltage must drop below 1V 

 

AC or DC for OFF.

6.  CONTROL PORT – 

One, 3.5mm 4-circuit mini jack used for all Controller and Keypad programming. It also accommodates 

 

factory firmware upgrades in conjunction with the 

FIRMWARE UPGRADE ON/OFF SWITCH. 

See: 

EZ-Tools MZC Programming 

 

Instructions

 for additional information.

7.  FIRMWARE UPGRADE ON/OFF SWITCH – 

One, two position switch enables the MZC-64 Control Port for Firmware Upgrades. See: 

 

EZ-Tools MZC Programming Instructions

 for additional information.

8.  COMMON IR OUTPUT – 

One, 3.5mm mini  jack outputs all IR commands from IR sensors and Keypads regardless of zone origin. 

 

POLARITY:

 TIP=SIGNAL; SLEEVE=GND.

9.  HI/LO SWITCH – 

One, two position switch, sets high or low IR power output to the Common IR Output jack. Set to the 

LO

 

 

setting when driving standard low power emitters (SpeakerCraft IRE-1.0, 2.0, 3.0 and 4.0). Set to 

HI

 when driving a high power 

 

emitter (SpeakerCraft IRE-5.0 Blaster) for teaching IR commands into learning remotes. 

HI OUTPUT: 

110mA;

 LO OUTPUT: 

13mA. 

 

CAUTION:

 The 

HI

 position will smoke low power emitters!

10.  COMMON STATUS OUT – 

One, 3.5mm mini jack will go high (+12V DC) when any zone is turned ON and will go LOW (under 1V 

 

DC) when the last zone is turned OFF. 

POLARITY:

 TIP=+12V DC; SLEEVE=GND. 

MAX OUTPUT:

 100 mA at 9.5V DC.

11.  L & R PRE-OUT – 

Two, RCA jacks, one pair per Zone, provide left and right line-level audio outputs for driving external high-

 

power/audiophile two-channel amplifiers in large or outdoor zones or a critical listening zone, or driving a multi-channel 

 

amplifier for additional rooms, (sub-zone expansion) where needed.

12.  KEYPAD – 

Four, RJ45 jacks, one per zone, connect zone keypads to the MZC via CAT5 or better. Configured for T568B Standard 

 

pin-out. Allows runs of up to 1000’.

13.  L & R SPEAKERS – 

Four, removable screw-down connectors, one terminal per zone, provide quick connection of the internal 

 

amplifiers to Zone stereo speaker pairs. 

WIRE GAUGE:

 14 to 28 AWG.

14.  IR OUT (Zone) – 

One, 3.5mm mini jack, one per zone, provides dedicated Zone IR output for exclusive control of a specific 

 

zone component. (i.e., a dedicated satellite receiver or DVD player, that cannot be controlled from any other zones). 

 

POLARITY:

 TIP=SIGNAL; SLEEVE=GND.

15.  VC/NVC – 

Four, two-position switches, one per zone, switch the PRE-OUT jacks to 

VC

 - internal Volume Control (variable, zone 

 

volume controlled by keypads or IR remote) or 

NVC

 - No Volume Control (fixed, zone volume controlled by in-wall volume 

 

control or volume control on an external device such as an A/V Receiver). In either case, the tone control action remains 

 

available for room “EQ” settings.

16.  IR LOOP – 

Six, 3.5mm mini jacks, one per Source, provide connections for an IR signal path for external common source com

 

ponents, when using multiple MZC-64’s in expanded systems. i.e. If using two MZC-64s, the SOURCE IR OUTS on the MZC Slave 

 

unit would connect to the appropriate SOURCE IR LOOPS on the MZC Master unit to pass Source IR commands between con

 

trollers from expanded zones. The IR OUTS on the Master connect to IR EMITTERS attached to the source components for 

 

source IR control from all zones. 

POLARITY:

 TIP=SIGNAL; SLEEVE=GND.

17.  IR OUT (Source) – 

Six, 3.5mm mini jacks, one per Source, output IR commands to external common source components. 

 

When a source is selected, from a keypad or remote control, IR commands are routed directly to that source. This allows 

 

selective control of multiple same-brand, same-model source components (multiple Satellite Receivers, DVD Players etc). 

 

POLARITY:

 TIP=SIGNAL; SLEEVE=GND.

18.  L & R LOOP (Source Left/Right Audio Loop) – 

Twelve, RCA jacks, two per Source, provide buffered left and right line-level 

 

audio outputs that are typically used to loop Source Audio signals to additional zone inputs on Slave MZC-64’s in expanded 

 

systems. i.e. The L & R LOOP on the MZC Master would connect to the appropriate L & R INPUT on MZC Slave 1. Slave 1 would 

 

then loop to Slave 2, etc. These outputs can also be used to drive local components, such as a local surround receiver, when 

 

not used for expansion.

19.  L & R INPUT (Source Left/Right Audio Input) – 

Twelve RCA jacks, two for each Source, provide left and right line-level audio 

 

signal inputs for up to six external common source components.

20.  IEC TYPE AC MAINS RECEPTACLE AND FUSE – 

One, Standard IEC 3-conductor AC line cord receptacle, connects to included AC 

 

power cord. Also houses the rear panel replaceable AC mains fuse (T5AL 250V).

3

Summary of Contents for MZC-64

Page 1: ...ms with multiple controllers external amplifiers multi room zones or when changing the layout of the keypad buttons it is highly recommended that the MZC 64 Hardware In stallation Instructions be used...

Page 2: ...EYPAD SPKRS L R ZONE 3 SOURCE 4 OUT IR LOOP L R INPUTS LOOP L R PRE OUT VC NVC IR OUT KEYPAD SPKRS L R ZONE 4 SOURCE 5 OUT IR LOOP L R INPUTS LOOP SOURCE 6 OUT IR LOOP L R INPUTS LOOP CONTACT CLOSURE...

Page 3: ...Configured for T568B Standard pin out Allows runs of up to 1000 13 L R SPEAKERS Four removable screw down connectors one terminal per zone provide quick connection of the internal amplifiers to Zone s...

Page 4: ...is on 2 KEYPAD EXPANSION Terminal This 16 pin header terminal is used to inter connect the EZ Pad modules for expansion as needed A ribbon cable is packed with each NKP 1 0 and FKP 1 0 for making the...

Page 5: ...ins into the keypad s EZ Connect Terminals and snap the levers in place Be sure RJA 1 1 pin orientation is correct prior to powering up the system CAT 5 cable should be configured in a pass through pi...

Page 6: ...YPAD SPKRS L R ZONE 4 SOURCE 5 OUT IR LOOP L R INPUTS LOOP SOURCE 6 OUT IR LOOP L R INPUTS LOOP CONTACT CLOSURE EXPANSION PORTS RS232 DATA I O PHONE PAGE IN DOORBELL STATUS IN 1 2 CONTROL PORT FIRMWAR...

Page 7: ...terminal using the included removable screw down con nectors 2 Strip approximately 1 4 inch of each lead and twist the stripped ends so there are no loose strands that can cause shorts 3 Carefully sl...

Page 8: ...Crosstalk Between Sources 65 dB 10 kHz S N Ratio Re Rated output 100 dB IEC A source inputs shorted Bass Control Range 10 dB 100 Hz Treble Control Range 10 dB 10 kHz CONTROL SECTIONS Contact Closures...