2.6. GENERAL INSTRUCTIONS FOR INSTALLATION
IN CUSTOM-MADE FURNITURE/FIREPLACE
CASINGS
• All minimum distances and installation dimensions must be observed
when designing the custom-made furniture.
• The base plate of the furniture must have sufficient load-bearing capac-
ity (the ebios insert weighs 88.5 kg).
• The ebios insert must be levelled and securely screwed on to the
furniture.
• The furniture should always be permanently attached to the wall or floor
and secured against accidental moving, knocking over and/or lifting.
Suitable fastening material should be used.
• All air inlets and rear vents must be kept clear and never blocked, as
otherwise a build-up of heat may occur.
Fire hazard!
• All objects (such as door fronts) must be kept clear of the hot air flow
above the ebios air outlet.
• The surfaces of the front cover (in particular, above the insert) must be
heat-resistant to 65°C.
2.6.1 MINIMUM FURNITURE/FIREPLACE CASING
DESIGN DIMENSIONS
• The front plate of the furniture unit should be of 2-part construction to
facilitate installation.
• The front plate cut-out size is 755x528 mm.
• The minimum distance between the top of the fire insert and the top of
the furniture unit is 15 mm.
• The minimum distance between the back of the fire insert and the back
of the furniture unit is 30 mm.
• The side distance between the fire insert and the side panel of the
furniture unit is 5 mm.
• The maximum panel thickness for the front cover is 25 mm.
The same minimum dimensions and distances apply when installing the unit
in a fireplace casing.
-Front view-
Front panel, 2-part
-Front view-