The following must be observed to ensure safe and easy transportation:
• The ebios-fire may only be lifted with transport aids from its rear side (if
required), especially if sack barrows are used.
• The tank must be empty during transportation.
Please notify your supplier immediately of any TRANSPORT DAMAGE.
Protect the enclosure and visible parts of the fireplace feature against soil-
ing and damage during assembly and transportation.
2.4. INSTALLATION LOCATION
When choosing the installation location for your ebios-fire please ensure the
unit is not directly exposed to major heat sources such as radiators, stoves,
etc. and that it is not installed in a room where high temperatures occur
(e.g. a sauna). External heating of the ethanol fireplace while the appliance
is not being used, may lead to the escape of the fuel from the tank. The fuel
will escape from the burner channel into the overflow tray. In this case,
please remove the burner before ignition and empty the overflow tray.
Your ebios-fire may not be installed:
• In stairwells, except in residential buildings comprising no more than
two dwellings
• In publicly accessible corridors.
• In garages
• In areas where highly flammable or explosive substances or com-pounds
are processed, stored or manufactured in quantities constituting an
ignition or explosion hazard.
• In badly ventilated areas
• In unsupervised publicly accessible areas.
• In areas that are not protected against crossventilation.
• On tables, furniture, shelves etc.
2.5 INSTALLATION / ASSEMBLY
The ebios insert is a ready-to-use unit for fitting into a custom-made piece
of furniture (combustible materials) or a custom-built fireplace casing (non-
combustible materials).
Custom-built fireplaces using the ebios insert do not require a flue.
The furniture or the fireplace casing containing the ebios insert must be
level and secured against tilting. Fix the wall unit to the wall and the free-
standing unit to the wall or to the floor. Observe the safety distances (Figs. 8
and 9 Radiant range). Back vents must not be closed. Place the burner, with
its safety pan and cover plate, in the unit’s designated receptacle.
Ensure that free standing units are installed on adequate load bearing floors.
In other case appropriate measures must be taken (for example a plate for
load distribution) to ensure load bearing.
Please use appropriate fastening material (wall-plugs, screws etc.) for wall
mounting.
Modifications to the design or construction of the ebios insert are NOT
permissible.