1.9  EXTRA PRECAUTIONS
1.9.1   Potential risk during plasma cutting

•   during the plasma cutting – plasma arc temperature exceeds several thousand °C,

•   large light radiation is accompanied when plasma cutting as a result of burning gases  

and the igniting of a plasma arc,

•  during the perforating and the plasma cutting may occurs molten metal splashes,

•  during the plasma cutting gases and fumes may occur intensively.

1.9.2. Risk of high temperature

Sources of heat accompanying to a process of plasma cutting come from: 

•  plasma arc,

•  high-temperature of the burner,

•  hot metal elements,

•  sparks and metal spatters,

•  liquid metal drops.

The effects of high temperature that may occur:

•  superficial burns – total destruction of the epidermis,

•  deep burns – the destruction of parts of the skin with sebaceous glands,

•  full burns – total destruction of the skin.

The methods of protection against the described threats that must be taken:

•   use the protective flame-resistant clothing such as: gloves, leather apron, protective footwear 

and headgear to protect face and eyes,

•   protect operators eyes through the use of special goggles with shade of DIN 6.

1.10  SYMBOLS USED IN INSTRUCTIONS

 

 

 

 

 

We use this symbol to pay your attention about important information.

2.  ELECTROMAGNETIC FIELDS (EMF)

Electric current flowing through any conductor causes localized electric and magnetic fields 

(EMF). All welders should use the following procedures in order to minimize the risk associated 

with exposure to EMF from the welding circuit:

•  Route the welding cables together – secure them with tape when possible.

•  Place your torso and head as far away as possible from the welding circuit

•  Never coil welding cables around your body.

•   Do not place your body between welding cables. Keep both welding cables on the same 

side of your body.

•  Connect the return cable to the workpiece as close as possible to the area being welded.

•  It is forbidden to sit or lean on power source while working.

•  Do not weld whilst carrying the welding power source or wire feeder.

 

 

  

WARNING!

 

The electromagnetic field (EMF) generated during welding (and allied processes) may interfere 

with the operation of implanted medical devices for example: cardiac pacemakers. Persons with 

implanted medical devices such as cardiac pacemakers are obliged to consult a doctor before 

starting to weld/plasma cutting and to exercise special caution during work. It is forbidden for 

such persons to be present in the vicinity of the place where welding/plasma cutting processes 

are realized without previous consultation of a doctor.

Summary of Contents for 45PFC

Page 1: ...User s manual Plasma cutter SPARTUS ProCUT 45PFC...

Page 2: ...nd performance during realization of the above mentioned processes SPAR TUS products are characterized by precisely such features they are primarily reliable and durable but they are also versatile We...

Page 3: ...6 1 9 Symbols used in instructions 7 2 ELECTROMAGNETIC FIELD EMF 7 3 ELECTROMAGNETIC COMPATIBILITY EMC 7 3 1 General informations 7 3 2 Assesment of area 8 3 3 Methods of reducing emmisions 8 4 CONFOR...

Page 4: ...ding operations are expected to be carried out All equipment should be placed so that it does not present a hazard in passageways on ladders or stairways etc Falling objects can cause injuries or kill...

Page 5: ...n dazzle and impair vision infrared heat radiation can damage skin and eyes Such radiation can be direct or reflected from surfaces such as bright metals and light colo ured objects 1 3 1 Eye and face...

Page 6: ...haust draught to keep vapours and gases away from the breathing zone When welding is carried out in a confined space operators should only be permitted to weld when other persons who have been instru...

Page 7: ...and located in an easily accessible place The surroundings of the work should be observed for an adequate period after its termination Hot spots and immediate surroundings should be observed until the...

Page 8: ...nce in an uncontrolled manner The welding wire tip may be sharp Never aim the burner tip of the welding torch at your face eyes or other people 1 7 4 Moving elements can be dangerous All protective el...

Page 9: ...use this symbol to pay your attention about important information 2 ELECTROMAGNETIC FIELDS EMF Electric current flowing through any conductor causes localized electric and magnetic fields EMF All weld...

Page 10: ...arc welding equipment the user shall make an assessment of potential elec tromagnetic interferences in the surrounding area The following shall be taken into account a other supply cables control cabl...

Page 11: ...and longer life of consumables The easy to use panel with an LCD display allows for smooth adjustment of the cutting current and setting the appropriate pressure In addition the cutter is equipped wit...

Page 12: ...IP21S Which means that it is intended to be used in closed and covered areas and suitable for use outdoors However it is not designed to be used outdoor during precipitation if it is not covered 6 2 T...

Page 13: ...d walls should be 50 cm 7 2 MOVEMENT AND HANDLING Please take special care when moving the machine It should be moved by using of specially installed transport handle If transport handle are damaged t...

Page 14: ...rol pins 3 Secure the connection by tightening the lock nut Check if the connection is tight 7 5 2 Assembly and connection the compressed air The compressed air or nitrogen which are used for plasma c...

Page 15: ...NEL Control cable Work clamp Power cable Compressor Plasma torch Elements of air filtration and air preparation in installation Cutting material 8 105RM 320 A 1 4 2 3 1 Screen 2 Mode switch 2T 4T 3 Cu...

Page 16: ...on Cutting Cutting Gun switch Gun switch Gas supply Gas supply Post Gas 2T 4T mode 2T mode To start cutting press the microswitch to start the plasma arc Releasing the microswitch will stop the cuttin...

Page 17: ...normally E12 Lack of gas message informs about the lack of air flow OTHER MESSAGES E01 Overheat message information about overheating The alarm will release after the period of fan cooling You can re...

Page 18: ...l spacers included to the plasma torch It is important to puncture properly through the material and guide the plasma burner at a right speed to maintain the proper penetration through material You sh...

Page 19: ...USER S MANUAL EN 17 VOLTAGE DIVIDER Scale selection 20 1 30 1 40 1 50 1 Number 1 ON 1 1 1 2 2 ON 2 2 3 3 3 ON 3 4 4 4 4 ON...

Page 20: ...ION 1 09600 Hand torch head to 25A 09602 Hand torch head to 40A 2 09605 Handle with microswitch set 3 07301 20 Microswitch 4 52531 Electrode 5 60028 Swirl ring 6 51316 06 Tip 0 6 51316 Tip 0 8 51316 0...

Page 21: ...sate from the filters Check the technical condition of the plasma torch and consumables At least once a month Regularly remove dust from inside the machine using compressed air The pressure should be...

Page 22: ...ween torch and power supply Work cable not connected to work piece Arc shuts off during operation and it will not restart Power supply is overheated Gas pressure too low Torch consumables worn CUTTING...

Page 23: ...on of high quality production excellentparametersandergonomics thesearefea turesoftheSPARTUS Masterseriesofdevices which werecreatedwithdemandingweldingjobsinmind Precision functionality excellent par...

Page 24: ...Videopresentation of products Subscribe to the channel SPARTUS INFO...

Reviews: