7.4  CONNECTING TO POWER SUPPLY

Requirements for power network parameters (voltage, permissible range of mains voltage 

fluctuations etc.) are given in the table with technical parameters of device and on the rating 

plate of cutter.

Before connecting the unit to the power source:

•  Check whether the parameters comply with the requirements for unit.
•  

Check: mechanical condition of the power cord and plug. The connection status of the power 

cord with plug and unit (loose not allowed). If the power cord or plug is damaged or loose 

connection is between them, it is forbidden to connect the cutter until fault has been rectified.

•   The cutter machine can be connected to the network only when the power socket is properly 

grounded.

7.5  CONNECTION OF THE DEVICE

   Before connecting the equipment and compressed air to the device, make sure that the unit is 

disconnected from the source power and the power switch 

6

 is in the OFF position.

7.5.1  Connecting the plasma torch

1.

   Before connecting the plasma torch, make sure that the control pins in the plug are connec-

ted like in scheme 

(see 7.7).

2.

   Connect the plug into central socket 

4

 

with due care and caution. Pay particular attention 

to the fitting of control pins.

3.

  Secure the connection by tightening the lock nut. Check if the connection is tight.

7.5.2  Assembly and connection the compressed air

   The compressed air or nitrogen which are used for plasma cutting should be free of contaminants such 

as particles, oil and or excessive moisture. For this purpose must be used special compressed air 

preparation elements such as: water separator, water filter, solid particles filter, oil filter, oil mist filter, etc.

   Use the proper pressure reducer which allows reduction of input pressure to the limit value.  

To an appropriate working pressure.

1.

  Make sure that the air filtering block is installed properly. 

2.

   Check the pressure coming out of the compressor or installation. Remember that the pres-

sure cannot be greater than 3.5 – 5bar - the maximum permissible inlet pressure to the filter 
block and to the device. 

3.

  Connect properly the air hose to the input terminal 

8

 

(see 7.3)

.

4.

  Make sure that there are no leaks. 

5.

  The working pressure is adjusted with the device turned on.

6.

  The value of working pressure should correspond to the values recommended 

(see 6.2)

.

7.5.3  Device connection

1.

  Connect properly plasma torch into socket 

(see 7.5.1)

.

2.

  Connect the compressed air into device 

(see 7.5.2.).

3.

  Connect return cable into SK socket „+” 

3

4.

  Connect the plasma cutter into power supply 

(see 7.4)

.

5.

  Turn on the unit by setting power switch 

6

 in the ON position.

6.

  Device is ready to cut.

Summary of Contents for 45PFC

Page 1: ...User s manual Plasma cutter SPARTUS ProCUT 45PFC...

Page 2: ...nd performance during realization of the above mentioned processes SPAR TUS products are characterized by precisely such features they are primarily reliable and durable but they are also versatile We...

Page 3: ...6 1 9 Symbols used in instructions 7 2 ELECTROMAGNETIC FIELD EMF 7 3 ELECTROMAGNETIC COMPATIBILITY EMC 7 3 1 General informations 7 3 2 Assesment of area 8 3 3 Methods of reducing emmisions 8 4 CONFOR...

Page 4: ...ding operations are expected to be carried out All equipment should be placed so that it does not present a hazard in passageways on ladders or stairways etc Falling objects can cause injuries or kill...

Page 5: ...n dazzle and impair vision infrared heat radiation can damage skin and eyes Such radiation can be direct or reflected from surfaces such as bright metals and light colo ured objects 1 3 1 Eye and face...

Page 6: ...haust draught to keep vapours and gases away from the breathing zone When welding is carried out in a confined space operators should only be permitted to weld when other persons who have been instru...

Page 7: ...and located in an easily accessible place The surroundings of the work should be observed for an adequate period after its termination Hot spots and immediate surroundings should be observed until the...

Page 8: ...nce in an uncontrolled manner The welding wire tip may be sharp Never aim the burner tip of the welding torch at your face eyes or other people 1 7 4 Moving elements can be dangerous All protective el...

Page 9: ...use this symbol to pay your attention about important information 2 ELECTROMAGNETIC FIELDS EMF Electric current flowing through any conductor causes localized electric and magnetic fields EMF All weld...

Page 10: ...arc welding equipment the user shall make an assessment of potential elec tromagnetic interferences in the surrounding area The following shall be taken into account a other supply cables control cabl...

Page 11: ...and longer life of consumables The easy to use panel with an LCD display allows for smooth adjustment of the cutting current and setting the appropriate pressure In addition the cutter is equipped wit...

Page 12: ...IP21S Which means that it is intended to be used in closed and covered areas and suitable for use outdoors However it is not designed to be used outdoor during precipitation if it is not covered 6 2 T...

Page 13: ...d walls should be 50 cm 7 2 MOVEMENT AND HANDLING Please take special care when moving the machine It should be moved by using of specially installed transport handle If transport handle are damaged t...

Page 14: ...rol pins 3 Secure the connection by tightening the lock nut Check if the connection is tight 7 5 2 Assembly and connection the compressed air The compressed air or nitrogen which are used for plasma c...

Page 15: ...NEL Control cable Work clamp Power cable Compressor Plasma torch Elements of air filtration and air preparation in installation Cutting material 8 105RM 320 A 1 4 2 3 1 Screen 2 Mode switch 2T 4T 3 Cu...

Page 16: ...on Cutting Cutting Gun switch Gun switch Gas supply Gas supply Post Gas 2T 4T mode 2T mode To start cutting press the microswitch to start the plasma arc Releasing the microswitch will stop the cuttin...

Page 17: ...normally E12 Lack of gas message informs about the lack of air flow OTHER MESSAGES E01 Overheat message information about overheating The alarm will release after the period of fan cooling You can re...

Page 18: ...l spacers included to the plasma torch It is important to puncture properly through the material and guide the plasma burner at a right speed to maintain the proper penetration through material You sh...

Page 19: ...USER S MANUAL EN 17 VOLTAGE DIVIDER Scale selection 20 1 30 1 40 1 50 1 Number 1 ON 1 1 1 2 2 ON 2 2 3 3 3 ON 3 4 4 4 4 ON...

Page 20: ...ION 1 09600 Hand torch head to 25A 09602 Hand torch head to 40A 2 09605 Handle with microswitch set 3 07301 20 Microswitch 4 52531 Electrode 5 60028 Swirl ring 6 51316 06 Tip 0 6 51316 Tip 0 8 51316 0...

Page 21: ...sate from the filters Check the technical condition of the plasma torch and consumables At least once a month Regularly remove dust from inside the machine using compressed air The pressure should be...

Page 22: ...ween torch and power supply Work cable not connected to work piece Arc shuts off during operation and it will not restart Power supply is overheated Gas pressure too low Torch consumables worn CUTTING...

Page 23: ...on of high quality production excellentparametersandergonomics thesearefea turesoftheSPARTUS Masterseriesofdevices which werecreatedwithdemandingweldingjobsinmind Precision functionality excellent par...

Page 24: ...Videopresentation of products Subscribe to the channel SPARTUS INFO...

Reviews: