![Spartherm STOVE-600 Installation And Operating Instructions Manual Download Page 15](http://html1.mh-extra.com/html/spartherm/stove-600/stove-600_installation-and-operating-instructions-manual_1340292015.webp)
15
4.3 CHIMNEY INSTALLATION
This wood stove is designed and approved for installation with the following brands of chimneys measuring 6”
and 7” (152 and 178mm) in diameter as well as a minimum of 15’ (4,6m) and maximum of 45’ (13,5m) in height.
4.3.1 LISTED CHIMNEYS
This appliance must be installed with a listed 6” /153mm and 7”/178,5mm chimney system approved under the
following standards: CAN-ULC S629(IN CANADA) OR UL 103HT(IN U.S.).
MAINTAIN CLEARANCES TO COMBUSTIBLES AS SPECIFIED IN THE CHIMNEY MANUFACTURERS INSTALLATION
INSTRUCTIONS. YOU MUST FOLLOW THE CHIMNEY MANUFACTURER’S INSTALLATION INSTRUCTIONS FOR
INSTALLATION OF ALL CHIMNEY COMPONENTS. USE APPROPRIATE SUPPORTS, CAPS, FLASHING AND SHIELDS
IN ACCORDANCE WITH THE CHIMNEY MANUFACTURERS INSTALLATION INSTRUCTIONS.
CAUTION: THE STRUCTURAL INTEGRITY OF THE FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED.
The table below shows the minimum chimney height requirements, wood stove included, according to the number
of elbows:
chimney
number of elbows
minimum height
straight installation
-
15’ (4.6 m)
1 - 15° offset
2 - 15° elbows
15’ (4.6 m)
2 - 15° offset
4 - 15° elbows
18’ (5.5 m)
1 - 30° offset
2 - 30° elbows
15’ (4.6 m)
2 - 30° offset
4 - 30° elbows
20’ (6.1 m)
* 1 - 45° offset
* 2 - 45° elbows
16’ (4.9 m)
* 2 - 45° offset
* 4 - 45° elbows
23’ (7.0 m)
* permitted only in Canada
Refer to building code to make sure the installation seals the penetration of the building envelope or refer to the
listed chimney installation manual.
4.3.4 EXAMPLES OF TYPICAL INSTALLATIONS
straight chimney installation
isolated chase chimney installation
Summary of Contents for STOVE-600