4. INSTALLATION
4.1 HEARTH EXTENSION
WARNING
INSTALL THE HEARTH EXTENSION ONLY AS ILLUSTRATED!
A 16” / 406 mm for USA, 18” / 459 mm for Canada,
minimum hearth extension in front of the stove made
of non combustible material is required.In front of the
unit, the hearth extension must extend 8” / 203 mm on
each side. Also there must an hearth extension under
the unit, which extend 8” on the rear side.
The non combustible material that is used must be
UL 1618.
4.1.1 600 AND 700
All floor protection materials must be non-combustible material.
FLOOR PROTECTECTOR MUST BE LISTED TO UL 1618 ember protection.
Configuration
SIDE WALL
TO UNIT
SIDE WALL TO
PIPE
BACK WALL
TO UNIT
BACK WALL
TO PIPE
CEILING OR ALCOVE
TO BOTTOM OF UNIT
STRAIGHT single wall pipe
11” / 279mm
22” / 559mm
16 1/2” / 412mm
18” / 457mm
84” / 2134mm
STRAIGHT double wall pipe
11” / 279mm
21 3/4” / 553mm
6 1/4 / 159mm
8” / 203mm
84” / 2134mm
CORNER
8” / 203mm
18” / 457mm
8” / 203mm
18” / 457mm
84” / 2134mm
MODULE CLEARANCES
clearances
description
A
8” / 203mm Canada
6” / 152mm USA
each clearances side of unit
B
8” / 203mm
hearth extension on t he rear side
C
16” / 406 mm for USA
18” / 459 mm for Canada
hearth extension length
D
single wall pipe = 18” / 475mm double wall
pipe = 8” / 203mm
back wall to pipe