INSTALLATION
MR25664
15
GENERAL INFORMATION
The following instructions will help you to mount your planer onto your prime mover. The
planer uses the quick-attach system for ease of installation. Therefore, if you know how to at-
tach your loader bucket, attaching the cold planer should prove no problem.
Remember to read all safety warnings, decals and operating instructions before operat-
ing the attachment. If there is any portion of this manual that you do not understand, contact
your dealer.
WARNING! THE HIGH FLOW PLANERS ARE DESIGNED FOR USE ON HIGH FLOW
HYDRAULIC SYSTEMS.
DO NOT ATTACH OR OPERATE ANY ATTACHMENT THAT EXCEEDS THE
RECOMMENDED LIFTING CAPACITY OF YOUR PRIME MOVER.
WARNING! READ MANUAL PRIOR TO INSTALLATION
Improper installation, operation, or maintenance of this equipment could result in se-
rious injury or death. Operators and maintenance personnel should read this manual,
as well as all manuals related to this equipment and the prime mover thoroughly
before beginning installation, operation, or maintenance.
FOLLOW ALL SAFETY
INSTRUCTIONS IN THIS MANUAL AND THE PRIME MOVER'S MANUAL(S).
INSTALLATION
NOTICE! Lubricate all grease fittings before connecting this product to your prime
mover's hydraulic system. Refer to Lubrication section and follow the instructions.
1.
Place this product on a firm, level surface that is large enough to safely accommodate
this product, your prime mover and all workers involved in the mounting process.
2.
Following all standard safety practices and the instructions for installing an attachment
in your prime mover operator
’s manual, install the attachment onto your loader.
WARNING! To avoid serious personal injury, make sure the attachment is securely
latched to the attachment mechanism of your unit. Failure to do so could
result in separation of the attachment from the prime mover.
3.
Relieve any pressure from the auxiliary hydraulic system. After making sure that there
is not any foreign matter on the hydraulic couplers connect the case drain coupler to the
case drain on your skid steer loader. NOTE: The case drain line must be connected first,
then the power and return hoses. When disconnecting the hoses, it is recommended to
disconnect the case drain line last.
4.
Connect the power and return couplers to the high flow auxiliary hydraulic system of your
skid steer loader. Route the hoses in such a fashion as to avoid pinching or chafing.
CAUTION! BE SURE CASE DRAIN COUPLER IS COMPLETELY ENGAGED. Immediate
hydraulic motor seal failure and planetary damage will occur if case drain
is not successfully connected.